The measurement of lymphocyte volume: importance of reference particle deformability and counting solution tonicity.

نویسندگان

  • G B Segel
  • G R Cokelet
  • M A Lichtman
چکیده

We have determined the influence of reference particle deformability and suspending buffer tonicity on the measurement of lymphocyte volume by an electronic particle volume analyzer. When the volume analyzer was standardized with latex spherules having a shape factor (fe) of 1.5, red cell volume was 96 cu micron and lymphocyte volume was 289 cu micron. The red cell volume corresponded closely to the true red cell volume; the true lymphocyte volume, however, was 218 cu micron when measured by the lymphocytocrit/lymphocyte count and 203 cu micron by wet lymphocyte weight and density (mean approximately 210 cu micron). The difference between the electronic volume (Ve) of 289 cu micron and true lymphocyte volume of 210 cu micron was due to the influence of lymphocyte deformability (shape factor) as it traverses the sizing aperture. Since the true volume equals the Ve/fe, the red cells with a shape factor near 1.0 were sized appropriately by this method. In contrast, the lymphocyte shape factor was 1.38; thus, the true lymphocyte volume was 289 cu micron/1.38 or 210 cu micron. The tonicity of the suspending solution also influenced the measurement of particle volume when osmotically inactive standard particles (e.g., latex spherules) were used as a reference. Whereas the true lymphocyte volume was 210 cu micron at 286 mosmole/liter, it was 194 cu micron at 330 and 229 cu micron at 250 mosmole/liter. The standard counting solution, Isoton, is hyperosmolar (330 mosmole/liter) and causes an 8% shrinkage of osmotically active cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Measurement of Lymphocyte Volume : Importance of Reference Particle Deformability and Counting Solution

We have determined the influence of reference particle deformability and suspending buffer tonicity on the measurement of lymphocyte volume by an electronic particle volume analyzer. When the volume analyzer was standardized with latex spherules having a shape factor (f.) of 1 .5. red cell volume was 96 cu m and lymphocyte volume was 289 cu m. The red cell volume corresponded closely to the tru...

متن کامل

Formulation and Clinical Evaluation of Povidone-Iodine Ophthalmic Drop

Ophthalmia neonatorum is generally defined as conjunctivitis occurring within one month of life. The sources of this infection are environmental organisms or the organisms colonized in the birth canal. Untreated infection can cause blindness, especially if the corresponding organisms areNeisseria gonorrhoeae, or Chlamydia trachomatis. Povidone-iodine ophthalmic solution is an effective antib...

متن کامل

On the Dependence of Soot Formation and Combustion on Swirling Combustion Furnaces: Measurement and Simulation

Soot concentration distribution is investigated both numerically and experimentally in methane-air diffusion flame. The experimental work is conducted with a cylindrical swirl stabilized combustor. Filter paper technique is used to measure soot volume fraction inside the combustor. The numerical simulation is based on the solution of the fully-coupled conservation equations for swirling turbule...

متن کامل

Formulation and Clinical Evaluation of Povidone-Iodine Ophthalmic Drop

Ophthalmia neonatorum is generally defined as conjunctivitis occurring within one month of life. The sources of this infection are environmental organisms or the organisms colonized in the birth canal. Untreated infection can cause blindness, especially if the corresponding organisms areNeisseria gonorrhoeae, or Chlamydia trachomatis. Povidone-iodine ophthalmic solution is an effective antib...

متن کامل

A method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow

Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 1981