Complex myograph allows the examination of complex muscle contractions for the assessment of muscle force, shortening, velocity, and work in vivo

نویسندگان

  • Niels Rahe-Meyer
  • Matthias Pawlak
  • Christian Weilbach
  • Wilhelm Alexander Osthaus
  • Hainer Ruhschulte
  • Cristina Solomon
  • Siegfried Piepenbrock
  • Michael Winterhalter
چکیده

BACKGROUND The devices used for in vivo examination of muscle contractions assess only pure force contractions and the so-called isokinetic contractions. In isokinetic experiments, the extremity and its muscle are artificially moved with constant velocity by the measuring device, while a tetanic contraction is induced in the muscle, either by electrical stimulation or by maximal voluntary activation. With these systems, experiments cannot be performed at pre-defined, constant muscle length, single contractions cannot be evaluated individually and the separate examination of the isometric and the isotonic components of single contractions is not possible. METHODS The myograph presented in our study has two newly developed technical units, i.e. a). a counterforce unit which can load the muscle with an adjustable, but constant force and b). a length-adjusting unit which allows for both the stretching and the contraction length to be infinitely adjustable independently of one another. The two units support the examination of complex types of contraction and store the counterforce and length-adjusting settings, so that these conditions may be accurately reapplied in later sessions. RESULTS The measurement examples presented show that the muscle can be brought to every possible pre-stretching length and that single isotonic or complex isometric-isotonic contractions may be performed at every length. The applied forces act during different phases of contraction, resulting into different pre- and after-loads that can be kept constant - uninfluenced by the contraction. Maximal values for force, shortening, velocity and work may be obtained for individual muscles. This offers the possibility to obtain information on the muscle status and to monitor its changes under non-invasive measurement conditions. CONCLUSION With the Complex Myograph, the whole spectrum of a muscle's mechanical characteristics may be assessed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of K+ Channel Blockade on Eccentric and Isotonic Twitch and Fatiguing Contractions in situ

K(+) channel blockers like 3,4-diaminopyridine (DAP) can double isometric muscle force. Functional movements require more complex concentric and eccentric contractions, however the effects of K(+) channel blockade on these types of contractions in situ are unknown. Extensor digitorum longus (EDL) muscles were stimulated in situ with and without DAP in anesthetized rats and fatigability was addr...

متن کامل

Effects of prestretch at the onset of stimulation on mechanical work output of rat medial gastrocnemius muscle-tendon complex.

Work output of rat gastrocnemius medialis (GM) muscle (N = 5) was measured for stretch-shortening contractions, in which initiation of stretch occurred prior to the onset of activation, and for contractions with an isometric prephase. Duration of the active prephase (prestretch and pre-isometric) varied from 20 to 200 ms. Subsequent shortening (from optimum length + 4 mm to optimum length -2mm)...

متن کامل

The role of series elastic structures in prestretch-induced work enhancement during isotonic and isokinetic contractions.

The influence of series elastic structures on the dynamics of the contractile machinery was examined in the gastrocnemius medialis (GM) of five male Wistar rats, with respect to enhancement of work of a muscle-tendon complex after active stretch. Imposed isotonic and isokinetic contractions were preceded by either an isometric phase (PI) or an active stretch (PS). The effects of fibre length di...

متن کامل

Shortening-induced force depression in human adductor pollicis muscle.

1. The effects of single isovelocity shortening contractions on force production of the electrically stimulated human adductor pollicis muscle were investigated in seven healthy male subjects. 2. Redeveloped isometric force immediately following isovelocity shortening was always depressed compared with the isometric force recorded at the same muscle length but without preceding shortening. The ...

متن کامل

تاثیر دما بر کاهش قدرت عضلانی ایزومتریک متعاقب تمرینات اکسنتریک در عضله گاستروکنمیوس داخلی ایزوله پرفیوز شده موش صحرائی

Background: The typical features of eccentric exercise-induced muscle damage are delayed-onset muscle soreness (DOMS) and prolonged loss of muscle strength. It has been shown that passive warmth is effective in reducing muscle injury. Due to the interaction of different systems in vivo, we used isolated perfused medial gastrocnemius skeletal muscle to study the direct effect of temperature on t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2008