Pentacam keratometric values unreliable for IOL power calculation after refractive surgery.

نویسندگان

  • Jennifer C Fan Gaskin
  • Chi-Ying Chou
  • Charles N J McGhee
چکیده

Pentacam Keratometric Values Unreliable for IOL Power Calculation After Refractive Surgery To the Editor: We read with interest the article by Gonen et al,1 which appeared in the August 2012 issue of the Journal of Refractive Surgery, on their study comparing keratometric data from 200 patients evaluated for refractive surgery using four different devices—an automated keratometer (KR 8800 [Topcon, Tokyo, Japan]), two Placido-based computerized topography systems (Dicon CT 200 [Vismed Inc, San Diego, California] and Allegro Topolyzer [WaveLight Inc, Sterling, Virginia]), and a Scheimpfl ug analyzer (Pentacam [Oculus Optikgeräte GmbH, Wetzlar, Germany]). The study revealed that although the mean simulated keratometry (Sim K) obtained with the Pentacam did not differ signifi cantly from the other three devices, the Pentacam gave rise to the greatest number of extreme outliers ( 2.00-diopter [D] difference) on Bland-Altman plots. In addition, the 95% limits of agreement for the Pentacam Sim K value compared to the other devices was approximately 1.35 D greater. The authors concluded that that the Pentacam data should be used with caution in intraocular lens (IOL) calculations and keratorefractive surgery analysis. The results observed by Gonen et al were echoed in our own unpublished prospective study assessing the accuracy and validity of keratometric values provided by the Pentacam for calculating IOL power following corneal refractive surgery. We prospectively evaluated patients requiring cataract surgery and, amongst other measures, assessed preand postoperative visual acuity, subjective refraction, automated keratometry, and Pentacam equivalent K-readings (for central 4.5-mm zone). Target refractions were calculated using surgeon-selected formulae incorporating Pentacam-calculated corneal power and were compared with postoperative manifest refraction. The Pentacam equivalent K-readings were compared with a “gold standard” K value, which was back-calculated, based on the postoperative refractive outcomes, using the Holladay 2 formula. Our study recruited 36 eyes from 25 patients and the mean age at corneal refractive surgery was 48 years; cataract surgery was typically ~10 years later. Eighteen eyes had undergone photorefractive keratectomy (PRK) and 18 underwent LASIK. Using Pentacam refractive corneal power, mean predicted refractive outcome (spherical equivalent) following cataract surgery was 0.28 0.47 D; the actual manifest postoperative refractive spherical equivalent was 0.03 1.20 D. The mean deviation from the desired postoperative cataract refractive outcome was 0.32 1.09 D. However, the mean absolute error (MAE) was 0.92 0.74 D, with 33% of eyes exhibiting an MAE of 1.00 D. Other studies refl ect these fi ndings.2-4 Interestingly, Kim et al5 used Pentacam true net corneal power to calculate the IOL power for eyes requiring cataract surgery following keratorefractive surgery. Although postoperative refraction was 0.50 D of intended in 70% of eyes (21/30), conversely, 25% of eyes had 0.75 D MAE compared to the desired refractive outcome. In a climate of refractive excellence, where surgeons target 0.25 D of refractive error, the postoperative PRK and LASIK keratometric values provided by the Pentacam no longer appear acceptable in the calculation of IOL power. With increasing numbers of “baby-boomers” who have already undergone refractive surgery looking for equal excellence in cataract outcomes, surgeons must continue the search for accurate and reproducible keratometric values following corneal refractive surgery. Jennifer C. Fan Gaskin, MBChB Chi-Ying Chou, MBChB Charles N.J. McGhee, PhD, FRCOphth Auckland, New Zealand

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia.

OBJECTIVES To describe the refractive results of cataract surgery after photorefractive keratectomy (PRK) for patients with myopia, and to find a more accurate method to predict intraocular lens (IOL) power in these cases. DESIGN Nonrandomized, retrospective clinical study. PATIENTS AND METHODS Nine patients (15 eyes) who underwent cataract surgery after prior PRK to correct myopia were ide...

متن کامل

Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position

PURPOSE To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). MATERIALS AND METHODS Clinical data from 25 eyes...

متن کامل

Intraocular lens power calculation for cataract surgery after photorefractive keratectomy.

OBJECTIVE To assess intraocular lens (IOL) power calculations in patients undergoing cataract surgery after excimer laser photorefractive keratectomy (PRK) for myopia. METHODS Four eyes of two patients underwent phacoemulsification with IOL implantation after PRK for myopia. The estimated refractive error that would have been induced had the IOL predicted for emmetropia been implanted was cal...

متن کامل

The Comparison of Central and Mean True-Net Power (Pentacam) in Calculating IOL-Power After Refractive Surgery

PURPOSE To compare the accuracy of central true net corneal power (cTNP) and mean true net corneal power (mTNP) of the Pentacam system to give a keratometry (K) reading for calculating IOL (intraocular lens) power in eyes following refractive surgery. METHODS Refraction, an automated K-reading (Km), cTNP and mTNP were measured for 15 eyes that required cataract surgery and had previously unde...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2013