Mechanical failure in intramedullary interlocking nails.

نویسندگان

  • A K Bhat
  • S K Rao
  • K Bhaskaranand
چکیده

PURPOSE To study clinical and mechanical factors that predispose to failure of interlocking nails. METHODS Between October 1996 and December 2002, 286 femoral fractures, 211 tibial fractures, and 47 humeral fractures were repaired using variously designed interlocking nails. Fracture pattern, level and site, nail size and type, weight bearing after nailing, and union status were reviewed after a mean follow-up of 22 months. RESULTS Nail failure occurred in 27 fracture repairs (17 femoral, 9 tibial, and one humeral; 13 from our institution and 14 referred from elsewhere). In 55% of failed repairs, the fracture was distal. A high rate of tibial nail failure was noted. CONCLUSION Distal fractures and stress concentration at the distal screws predispose to interlocking nail failure and can be prevented by protected weight bearing combined with the use of longer and larger nails. Routine supplementary cancellous bone grafting is unnecessary during renailing surgery when adequate reaming and a larger nail are used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intramedullary Interlocking Nail Fixation in Dogs and Cats: Biomechanics and Instrumentation*

of diaphyseal long bone fractures. Interlocking nails have transverse cannulations that accommodate transcortical screws, allowing surgeons to firmly fix the rod within the medullary canal, thereby effectively neutralizing bending, rotational, and axial forces that act on fractures. Interlocking nails have become increasingly To counter axial and rotational forces, intramedullary nails were dev...

متن کامل

The functional results of tibial shaft fractures treated with intramedullary nail compressed by proximal tube.

Nailing of tibial shaft fractures is considered the gold standard surgical method by many surgeons. The aim of this retrospective study was to investigate and compare the clinical outcome of tibial shaft fractures treated with intramedullary nails compressed by proximal tube and conventional intramedullary interlocking nails. Fifty-seven patients with tibial shaft fractures, treated with intram...

متن کامل

Adult tibial shaft fractures – different patterns, various treatments and complications

BACKGROUND Tibial Fractures constitute a large number of emergency operations in most trauma centers. There are different approaches for tibial fractures. To our knowledge, there is insufficient evidence to consider post-operative complications in relation to both surgical methods and the types of fractures. Our purpose is to report our experience regarding the efficacy and complications associ...

متن کامل

Intramedullary nails with distal interlocking screws locked to the nail may have higher fatigue strength in comminuted supracon

Figure 2. Specimen mounted on the MTS. Intramedullary nails with distal interlocking screws locked to the nail may have higher fatigue strength in comminuted supracondylar femur fractures McDonald, E;, Fischer, J; Bartlett, T; Buckley, J.M; Pekmezci, M, +Kandemir, U +Biomechanical Testing Facility, UCSF/SFGH Orthopaedic Trauma, University of California at San Francisco, San Francisco, CA, USA D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 2006