A multi-laboratory evaluation of a clinically-validated incurred quality control material for analysis of allergens in food.

نویسندگان

  • Phil E Johnson
  • Neil M Rigby
  • Jack R Dainty
  • Alan R Mackie
  • Ulrike U Immer
  • Adrian Rogers
  • Pauline Titchener
  • Masahiro Shoji
  • Anne Ryan
  • Luis Mata
  • Helen Brown
  • Thomas Holzhauser
  • Valery Dumont
  • Jill A Wykes
  • Michael Walker
  • Jon Griffin
  • Jane White
  • Glenn Taylor
  • Bert Popping
  • René Crevel
  • Sonia Miguel
  • Petra Lutter
  • Ferdelie Gaskin
  • Terry B Koerner
  • Dean Clarke
  • Robin Sherlock
  • Andrew Flanagan
  • Chun-Han Chan
  • E N Clare Mills
چکیده

A dessert matrix previously used for diagnosis of food allergies was incurred with pasteurised egg white or skimmed milk powder at 3, 6, 15 and 30 mg allergen protein per kg of dessert matrix and evaluated as a quality control material for allergen analysis in a multi-laboratory trial. Analysis was performed by immunoassay using five kits each for egg and milk (based on casein) and six 'other' milk kits (five based on β-lactoglobulin and one total milk). All kits detected allergen protein at the 3 mg kg(-1) level. Based on ISO criteria only one egg kit accurately determined egg protein at 3 mg kg(-1) (p=0.62) and one milk (casein) kit accurately determined milk at 6 (p=0.54) and 15 mg kg(-1) (p=0.83), against the target value. The milk "other" kits performed least well of all the kits assessed, giving the least precise analyses. The incurred dessert material had the characteristics required for a quality control material for allergen analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A peanut quality control material to improve allergen analysis – How difficult can it be?

Flawed allergen analysis hinders detection and measurement of allergens, which is important for allergen risk management in food labelling, in-factory cleaning and threshold levels. ELISA, DNA and MS can be used to detect food allergens but there are quantification problems with all three. ELISA is currently the most commonly applied technique however, although it can detect the presence of mos...

متن کامل

Correlation of results between validated in-house analysis method with new pharmacopeia monograph for analysis of Sitagliptin Phosphate API

Having validated analysis methods for medicinal ingredients is attractive for pharmaceutical companies. When a new molecule is introduced to the market, there is not any pharmacopeial analysis method for that. After publishing official methods, correlation between validated in-house methods and the official one could stablish the value of the in-house method. Sitagliptin phosphate is a new anti...

متن کامل

Efficiency Evaluation of Medical Diagnostic Laboratories Using Data Envelopment Analysis in Isfahan, Iran

Abstract Background and Objective: Multi-criteria comparison between laboratories is important for laboratory management to improve performance and for policymakers to make strategic decisions. In this study, those aspects of performance are considered that are beyond the traditional evaluation carried out by checklist. Material and Methods: After the identifying the effective m...

متن کامل

Evaluation of the Frequency of Food Allergens by Skin Prick Test in Children with Atopic Dermatitis

Background: The role of food allergy in atopic dermatitis (AD) is controversial. The aim of this study was to determine the frequency of food allergens in children with AD. Method: Fifty one atopic dermatitis children aged 6 months to 5 years entered our study. The severity of AD was determined by scoring index of AD (SCORAD). Skin prick test (SPT) was done using 15 allergens including the whit...

متن کامل

I-5: Semen Analysis - Clinical Laboratories; Is Standardization Applied?

Reduced semen quality is commonly claimed to be one of the main signs of male infertility and thus, analysis of semen is recommended as the cornerstone of a male fertility investigation. However, to control possible sources of physiological and methodological variation, and to generate reliable information on semen quality that can be accurately compared across different laboratories, semen ana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Food chemistry

دوره 148  شماره 

صفحات  -

تاریخ انتشار 2014