Microleakage of two fluoride-releasing sealants when applied following saliva contamination.

نویسندگان

  • Praphasri Rirattanapong
  • Kadkao Vongsavan
  • Rudee Surarit
چکیده

The purpose of this in vitro study was to evaluate microleakage of two fluoride-releasing sealants in saliva contaminated and non-contaminated conditions. Twenty-four human third molars were randomly assigned to two groups: saliva contaminated and saliva non-contaminated teeth. In the contaminated group, the teeth were contaminated with 0.02 ml artificial saliva for 20 seconds and blowed dry afterward. Each group was divided into two subgroups: Group A, a fluoride-releasing resin sealant marketed as Clinpro and Group B, a glass-ionomer sealant marketed as Fuji VII. After sealant application, all the teeth were thermocycled for 2,000 cycles and coated with nail varnish 1.0 mm from the sealed areas. The teeth were stained with 2% methylene blue dye for 24 hours and sectioned in the bucco-lingual direction. Dye penetration (microleakage) was examined with a 25x polarized light microscope and measured by a computerized-calculated method. Data were compared with the Mann-Whitney U test at significance level of p<0.05. A comparison of the two types of sealant revealed microleakage of the glass-ionomer sealant was present but there was no significant difference between the saliva contaminated and saliva non-contaminated teeth. Microleakage of the fluoride-releasing resin sealant was present and was greater among the saliva-contaminated teeth than the saliva non-contaminated teeth. The glass-ionomer sealant had significantly greater microleakage than the fluoride-relasing resin-based sealant in both the saliva-contaminated and saliva non-contaminated teeth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Microleakage in Fissure Sealants following Contamination with Artificial Saliva at Different Curing Times with or without using bonding agent

Background and Aim: One of the important factors in microleakage of fissure sealants is saliva contamination. Researchers believe that applying bonding agents can reduce the microleakage. The present study compared the microleakage of a fissure sealant contaminated with artificial saliva at different curing times with or without using a bonding agent. Materials and Methods: In this in-vitro ...

متن کامل

Microleakage and penetration ability of resin sealant versus bonding system when applied following contamination.

PURPOSE The purpose of this study was to evaluate the microleakage and penetration ability of sealing materials applied under different conditions of contamination. METHODS One hundred twenty extracted human molar teeth were randomly assigned to 12 groups. The treatment groups were defined by the combination of sealing materials (Concise; Optibond system; Optibond system plus Concise) and 4 s...

متن کامل

Formulation and characterization of antibacterial fluoride-releasing sealants.

PURPOSE The purpose of this study was to formulate and characterize experimental antibacterial fluoride-releasing sealants and compare them with commercial sealants for fluoride release, recharge, adhesion, and microleakage. METHODS Two experimental sealants (Exp-1, Exp-2) containing a synthesized antibacterial fluoride-releasing monomer and fluoride-releasing filler were formulated. Exp-2 al...

متن کامل

Marginal microleakage of triage sealant under different moisture contamination.

PURPOSE Glass ionomer sealants (GISs) are promoted in pediatric dentistry for their moisture-friendly properties. This study's purpose was to investigate the marginal leakage of a glass ionomer sealant (Fuji Triage) under different moisture environments. METHODS Eighty extracted teeth were distributed into 4 groups: (1) control; (2) saliva contamination with 1-second air-thinning; (3) saliva ...

متن کامل

Microleakage, adaptation ability and clinical efficacy of two fluoride releasing fissure sealants.

BACKGROUND/AIM Retention of fissure sealants and good adaptation to enamel are essential for their success. Fluoride releasing resin-based materials are widely accepted for pit and fissure sealing, but newly designed glass ionomers can serve as a good alternative. The aim of this study was to evaluate microleakage and sealing ability in vitro, and to clinically assess two fluoride releasing fis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Southeast Asian journal of tropical medicine and public health

دوره 44 5  شماره 

صفحات  -

تاریخ انتشار 2013