Evaluation of the Radiation Dose–Volume Effects of Optic Nerves and Chiasm by Psychophysical, Electrophysiologic Tests, and Optical Coherence Tomography in Nasopharyngeal Carcinoma

نویسندگان

  • Ozlem Ozkaya Akagunduz
  • Suzan Guven Yilmaz
  • Deniz Yalman
  • Berna Yuce
  • Elif Demirkilinc Biler
  • Filiz Afrashi
  • Mustafa Esassolak
چکیده

PURPOSE To evaluate the radiation dose-volume effects of optic nerves and chiasm by visual psychophysical, electrophysiologic tests, and optical coherence tomography in patients with locally advanced nasopharyngeal carcinoma. MATERIALS AND METHODS A series of visual tests including visual acuity, visual field, contrast sensitivity, visual evoked potential, and optical coherence tomography were administered to 20 patients with locally advanced (T3-T4) nasopharyngeal carcinoma who were treated with definitive chemoradiotherapy. Volume that received 55 Gy (V55), mean dose ( Dmean), highest dose to 5% of the volume (D5), and maximum dose (Dmax) for optic nerves and chiasm were evaluated for each patient. Cutoff values were identified as V55: 50%, Dmean: 50 Gy, D5: 55 Gy, and Dmax: 60 Gy. The effects of radiation dose-volume on ophthalmologic tests were evaluated. RESULTS Ophthalmological evaluation revealed optic neuropathy with simultaneous retinopathy in 6 eyes of 4 patients and radiation retinopathy alone in both eyes of 1 patient. Regarding radiation dose-volume effects of the optic nerve, significant detrimental effect of all parameters was observed on visual acuity. Visual field and contrast sensitivity were affected significantly with V55 ≥ 50% and Dmean ≥ 50 Gy. Visual evoked potential latency was affected significantly with Dmean ≥ 50 Gy, D5 ≥ 55 Gy, and Dmax ≥ 60 Gy. For the chiasm, significant detrimental effect of all parameters was observed on visual acuity as well. Retinal nerve fiber layer thickness and visual evoked potential amplitude were not affected by any of the dose-volume parameters neither optic nerves nor chiasm. CONCLUSION The volume receiving the threshold dose, mean dose, and 5% of the volume receiving the maximum dose are important parameters besides maximum dose to optic nerves and chiasm. A comprehensive ophthalmological evaluation including visual field, contrast sensitivity, visual evoked potential latency, and amplitude should be performed for these patients. Visual evoked potential latency is an objective predictor of vision loss before the onset of clinical signs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the effects of dental filling material artifacts on IMRT treatment planning in patient with nasopharyngeal cancer

Background: Presence of artifacts, caused by dental filling high-Z materials (DFM), on intensity-modulated radiation therapy (IMRT) treatment plan CT images may lead to uncertainty in head and neck calculated dose distributions. Hence, the purpose of this study was to investigate the effects of DFM on the IMRT calculated dose distribution and consequent radiobiological derived outcomes for naso...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Evaluation of the effect of dental filling material on IMRT treatment planning in patient with nasopharyngeal cancer

Introduction: Presence of dental filling material (DFM) such as amalgam in treatment patient with nasopharyngeal cancer (NPC) is common. Streaking artifact Arising from this high density material in computed tomography (scan), may lead to perturbation in dose calculation and dose delivery. Widespread performance of intensity-modulated radiotherapy (IMRT) for NPC using anterior...

متن کامل

The importance of the optimal volume in the treatment of locally recurrent nasopharyngeal carcinoma; brachytherapy or stereotactic radiotherapy?

Introduction: Nasopharyngeal carcinoma (NPC) is commonly known as a radiosensitive tumor with the initial good response to radiation. Despite the improved outcome in loco regional control by the introduction of combining treatment, modern radiotherapy techniques and enhanced imaging studies, local recurrent after primary treatment with rate ranges from 15-58% in 5 years, stil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2017