Cryosurgical ablation of the atrioventricular node-His bundle: long-term follow-up and properties of the junctional pacemaker.
نویسندگان
چکیده
We used a cryosurgical technique to ablate the atrioventricular (AV) node-His bundle in twenty-two selected patients with disabling supraventricular tachyarrhythmias unresponsive to medical management. Successful AV block was achieved in seventeen. There was no intraoperative mortality and significant surgical complications were not encountered. Electrophysiologic studies performed 7-10 days after surgery revealed that the subsidiary pacemaker had a narrow QRS complex morphology and a mean cycle length of 1244 msec. Isoproterenol (1-4 microgram/min i.v.) significantly increased (p less than 0.01) the rate of the subsidiary pacemaker (mean maximum response 1008.3 msec); atropine (2 mg i.v.) had no effect on its rate. The cycle length of the subsidiary pacemaker during long-term follow-up (mean 14.8 months) showed a small but significant (p = 0.024) increase (mean cycle length 1430 msec). Treadmill exercise in seven patients did not result in the subsidiary pacemaker exceeding the rate of the implanted demand pacemaker set at 70 beats/min. The properties of the subsidiary pacemaker suggest an intra-Hisian site of impulse formation.
منابع مشابه
ORIGINAL ARTICLES Cryosurgical Ablation of the Atrioventricular Node-His Bundle: Long-term Follow-up and Properties of the Junctional Pacemaker
We used a cryosurgical technique to ablate the atrioventricular (AV) node-His bundle in twenty-two selected patients with disabling supraventricular tachyarrhythmias unresponsive to medical management. Successful AV block was achieved in seventeen. There was no intraoperative mortality and significant surgical complications were not encountered. Electrophysiologic studies performed 7-10 days af...
متن کاملCryosurgical ablation of the A-V node-His bundle: a new method for producing A-V block.
A cryosurgical instrument was used to ablate atrioventricular conduction. The procedure was carried out in 20 dogs and subsequently in three patients with drug resistant, life-threatening supraventricular tachycardias. In patients, the cryosurgical unit lowered the temperature of the His bundle area to 0 degrees C, effecting complete but reversible heart block. Rewarming resulted in resumption ...
متن کاملAntegrade slow bypass conduction after closed-chest ablation of the His bundle in permanent junctional reciprocating tachycardia.
A case of permanent junctional reciprocating tachycardia in a 36-year-old woman successfully treated with closed-chest interruption of the His bundle is reported. Tachycardia had lasted for 14 years and showed a retrograde P wave (P') and RP' longer than PR' interval. The tachycardia used an anomalous pathway with a long conduction time in the retrograde direction. The atrial end of the anomalo...
متن کاملCryosurgical Ablation of the A-V Node-His Bundle
A cryosurgical instrument was used to ablate atrioventricular conduction. The procedure was carried out in 20 dogs and subsequently in three patients with drug resistant, life-threatening supraventricular tachycardias. In patients, the cryosurgical unit lowered the temperature of the His bundle area to 0°C, effecting complete but reversible heart block. Rewarming resulted in resumption of norma...
متن کاملCryosurgical treatment of atrioventricular node reentrant tachycardia.
Paroxysmal supraventricular tachycardia most commonly arises from reentry within the atrioventricular (AV) node. Although ablation of the His bundle has gained popularity for treating patients with AV node reentrant tachycardia refractory to medical therapy, undesirable sequelae include complete heart block and the necessity for a permanent pacemaker. To obviate this limitation, we have develop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 61 1 شماره
صفحات -
تاریخ انتشار 1980