Studies of blood flow in aorta-to-coronary venous bypass grafts in man.
نویسندگان
چکیده
Pressure-flow measurements were obtained from the vein graft of 57 patients undergoing a single aorta-to-coronary bypass procedure. The flow contour was similar to phasic left coronary artery flow in dogs except for a transient increase during systole possibly related to elongation of the graft. Flow was highest during bypass and decreased to a stable value 30 min after bypass. In 42 patients, flow at this time was 35+/-2 cm(3)/min (mean+/-sem).NO CORRELATIONS WERE DEMONSTRATED BETWEEN FLOW AND THE FOLLOWING: left vs. right grafts, presence or absence of collaterals, total vs. partial block, or the presence or absence of ventricular dyskinesis. In 32 patients, no correlation between these anatomic findings and the presence of reactive hyperemia was demonstrated. In 17 patients, occlusion of the graft for 10 sec resulted in a mean 51.5% flow debt repayment. In nine patients, injection of 0.3 mug of isoproterenol into the graft increased flow from 45+/-6 to 69+/-9 cm(3)/min within 4-7 sec without changes in rate, pressure, time derivative of left ventricular pressure (LV dp/dt), or left ventricular end diastolic pressure (LVEDP). Maximum increases to 87+/-10 cm(3)/min occurred 12-20 sec after injection with concomitant changes in these parameters. Intravenous infusion of norepinephrine did not change vascular resistance, whereas phenylephrine did. In six patients, injection of 0.2 mug of norepinephrine into the graft decreased flow from 49+/-6 to 25+/-5 cm(3)/min within 5-8 sec. Intravenous infusion of 0.15 mg of nitroglycerin decreased coronary vascular resistance from 2.7+/-0.4 to 2.3+/-0.3 mm Hg/cm(3) per min. In five patients, 0.12 mg of nitroglycerin injected into the graft increased flow from 46+/-7 to 71+/-13 cm(3)/min and lasted 20-40 sec.
منابع مشابه
Aortocoronary bypass graft. Initial blood flow through the graft, and early postoperative patency.
Intraoperative measurements of blood flow were made in 70 patients in whom a total of 103 venous bypass grafts had been inserted from the aorta to the right, the left anterior descending, or the circumflex coronary artery. Cineangiographic evaluation of graft patency was performed in all patients. Overall patency rate was 90.3%. Flow in all bypass grafts averaged 68 ml/ min. All grafts with flo...
متن کاملEvaluation of venous bypass grafts from aorta to coronary artery by inert gas desaturation and direct flowmeter techniques.
Blood flow through aorta-to-coronary artery bypass grafts has been measured selectively in 16 patients at or within 6 wk after operation. Inert gas desaturation curves were obtained from coronary venous blood samples after a 7-15 min infusion of dissolved H(2) directly into the graft. Samples were analyzed chromatographically and curves resolved to 1-3% of initial H(2) concentrations. Average f...
متن کاملPatency of saphenous vein coronary artery bypass grafts from the vascular prosthesis of the ascending aorta.
BACKGROUND Patients who have Stanford type A aortic dissection with impaired coronary arteries or who have aneurysms from the ascending aorta to the aortic arch with coronary artery disease need coronary artery bypass grafting (CABG) with tube graft replacement of the ascending aorta simultaneously. When vein grafts are used for CABG in these patients, the proximal anastomoses of vein grafts ar...
متن کاملHemodynamic changes and related factors in patients undergoing coronary artery bypass grafting surgery
Introduction: Coronary artery diseases are the primary and most common cause of death in all ages. ‎Coronary artery bypass grafting (CABG) surgery as a common treatment intervention is considered ‎necessary in patients with coronary artery disease. Complications may occur during and after ‎‎(CABG) surgery. Among major complications are hemodynamic changes after surgery which is ...
متن کاملAdaptive mechanisms of arterial and venous coronary bypass grafts to an increase in flow demand.
OBJECTIVE To compare the mechanisms by which arterial and venous grafts increase their flow during pacing induced tachycardia, early and later after coronary bypass surgery. DESIGN 43 grafts (13 epigastric artery, 15 mammary artery, 15 saphenous vein) evaluated early (9 (3) days (mean (SD)) after bypass surgery were compared with 41 other grafts (15 epigastric, 11 mammary, 15 saphenous vein) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of clinical investigation
دوره 51 10 شماره
صفحات -
تاریخ انتشار 1972