WE-G-217A-03: Respiratory-Related External/Internal Motion Based MR Image Reconstruction Using Dynamic Keyhole for Real-Time Tumor Monitoring.
نویسندگان
چکیده
PURPOSE It is aim to test the hypothesis that a dynamic keyhole MRI reconstruction technique using external/internal respiratory surrogate position reduces acquisition time while retaining image quality for real-time tumor monitoring, compared to the conventional keyhole technique. METHODS 46 thoracic MRI studies with 13 healthy human subjects have been acquired using a 3T GE MRI. Acquired MR images were reconstructed using zero-filling, conventional keyhole and the proposed respiratory motion based dynamic keyhole techniques; resultant images were then compared for image quality. Undersampled k-space rate in the phase encoding direction was determined based on the difference between the original image and the reconstructed image. The position of abdominal muscles and diaphragm were used to determine any excess data that exists in the overlaid temporal data. In addition, the feasibility of the dynamic keyhole method was applied using lung tumor MR images. RESULTS The result from dynamic keyhole using respiratory motion demonstrated significant improvement compared with the zero-filling and conventional keyhole methods. Firstly, the dynamic keyhole method using external respiratory motion had an overlaid average of 79.7% (204 lines) of 256 lines from 46 datasets, compared to 63.9% in zero-filling and 74.3% in conventional keyhole. Secondly, dynamic keyhole method using internal diaphragm motion had an overlaid average of 84.5% (216 lines) of 256 lines from all datasets compared to 67.1% and 77.8% or zero-filling and conventional keyhole, respectively. Lastly, dynamic keyhole has been validated with one dataset involving lung tumor MR images. Image blurring artifacts and inferior resolution were not present in the final MR images using dynamic keyhole. CONCLUSIONS Dynamic keyhole method using respiratory external/internal surrogate motion has been proposed to reconstruct MR images without image artifacts and with superior resolution. This method is applicable to MR images targeting lungs and other organs affected by respiratory motion for real-time tumor motion monitoring.
منابع مشابه
A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates
Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملA quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
متن کاملMR compatible sensor for motion artifact corrected reconstruction method
INTRODUCTION: Patient motion, especially respiratory and cardiac motion, leads to artifacts which could damage the quality of Magnetic Resonance Imaging (MRI) and make the resulting diagnosis less accurate. If such motion occurs during MRI acquisitions, it has been shown that, knowing this motion, it is possible to invert the process of artifact production and to reconstruct a motion compensate...
متن کاملJoint surface reconstruction and 4D deformation estimation from sparse data and prior knowledge for marker-less Respiratory motion tracking.
PURPOSE The intraprocedural tracking of respiratory motion has the potential to substantially improve image-guided diagnosis and interventions. The authors have developed a sparse-to-dense registration approach that is capable of recovering the patient's external 3D body surface and estimating a 4D (3D + time) surface motion field from sparse sampling data and patient-specific prior shape knowl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part28 شماره
صفحات -
تاریخ انتشار 2012