A Compliant Telescopic Limb with Anisotropic Stiffness
نویسندگان
چکیده
Soft limbs with anisotropic stiffness are common in nature and enable animals to solve a variety of tasks, including locomotion and manipulation. This mixture of hardness and softness enables animals to efficiently control the unpredictable contact forces that occur while performing such tasks. A challenge for soft robotics is to create artificial limbs that mimic natural mixtures of hardness and softness for use as a building block for soft, adaptable robots. This article presents the design of a novel pneumatic limb module with adjustable length and anisotropic stiffness. The artificial limb is designed with a rigid telescopic endoskeleton inside a rubber bellow, which we show is able to resist buckling, while remaining externally soft. Finally, we present the design of a hexapod walker based on the limb units.
منابع مشابه
Leg stiffness increases with gait speed to maximize propulsion energy during push - off
Compliant walking models have been used to account for the gait dynamics associated with compliant lower limbs [1, 2], and leg compliance has been quantified as a form of vertical lower limb stiffness [3]. However, the vertical stiffness of the lower limb has been defined by the ratio of the force change to the displacement change based on a formulation of Kvert ≈ ΔF/Δx without considering a fu...
متن کاملEffects of acute and chronic interval sprint exercise performed on a manually propelled treadmill on upper limb vascular mechanics in healthy young men
Interval sprint exercise performed on a manually propelled treadmill, where the hands grip the handle bars, engages lower and upper limb skeletal muscle, but little is known regarding the effects of this exercise modality on the upper limb vasculature. We tested the hypotheses that an acute bout of sprint exercise and 6 weeks of training induces brachial artery (BA) and forearm vascular remodel...
متن کاملتاثیر سرعت استارت دویدن بر سفتی اندام تحتانی در دونده های سرعتی
Objective: Lower extremity stiffness is associated with variables such as the frequency and length of running steps, the amount of muscle force and power production. Previous studies showed contradictory findings regarding the relationship between lower extremities joints stiffness and start velocity. Sprint start can be highly affected by two key components of lower limb stiffness, namely, for...
متن کاملInteractions with Compliant Loads Alter Stretch Reflex Gains but not Intermuscular Coordination Running Head: Modulation of multijoint stretch reflexes
The human motor system regulates arm mechanics to produce stable postures during interactions with different physical environments. This occurs partly via involuntary mechanisms, including stretch reflexes. Previous single joint studies demonstrated enhanced reflex sensitivity during interactions with compliant environments, suggesting reflex gain increases to enhance limb stability when that s...
متن کاملPhysiological basis of limb impedance modulation during free and constrained movements Running head: Physiological mechanisms for limb impedance modulation
Arm stiffness is a critical factor underlying stable interactions with the environment. When the hand moves freely through space, a stiff limb would most effectively maintain the hand on the desired path in the face of external perturbations. Conversely, when constrained by a rigid surface, a compliant limb would allow the surface to guide the hand while minimizing variations in contact forces....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Front. Robotics and AI
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017