Physical Parameter Identification of Nonlinear Base-Isolated Buildings Using Seismic Response Data

نویسندگان

  • Chao Xu
  • J. Geoffrey Chase
  • Geoffrey W. Rodgers
چکیده

Base isolation is an increasingly applied earthquake-resistant design technique in highly seismic areas. Examination of the actual performance of isolated structures in real earthquake has become a critical issue. In this paper, a new computational method for system identification is proposed for obtaining insight into the linear and nonlinear structural properties of based-isolated buildings. A bilinear hysteresis model is used to model the isolation system and the superstructure is assumed linear. The method is based on linear and nonlinear regression analysis techniques. Response time histories are divided into different loading or unloading segments. A one-step multiple linear regression is implemented to simultaneously estimate storey stiffness and damping parameters of the superstructure. A two-step regression-based procedure is proposed to identify the nonlinear physical parameters of the isolation system. First, standard multiple linear regression is implemented to deduce equivalent linear system parameters. Analysis of the varying equivalent linear system parameters with displacement is used to distinguish linear and nonlinear segments. Second, nonlinear regression is applied for the nonlinear segments to obtain nonlinear physical parameters. A 3-storey base-isolated building was simulated to real earthquake ground motions and recorded responses were used to demonstrate the feasibility of the proposed † Corresponding author. Tel.: +86 029 88493620 E-mail address: [email protected] (C. Xu), [email protected] (J. G. Chase), [email protected] (G. W. Rodgers).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time segmented least squares identification of base isolated buildings

In this article two new approaches are presented for time domain identification of base isolated buildings from recorded response during earthquakes: (1) a least squares technique with time segments is developed to identify the piece-wise linear system properties; and (2) an observer is used to estimate the unmeasured states and initial conditions of different time segments. In base isolated bu...

متن کامل

Evaluation of Seismic Vulnerability of Reinforced Concrete Buildings Adjacent to the Deep Excavations

In this study, the effect of deep excavation on the seismic response of RC moment resisting building systems has been studied. Deep excavation can cause significant changes in the stress and strain levels of soil environment and also changes in the propagation of seismic waves. This leads to permanent displacements in the foundation system. In this study, three RC building systems, i.e. 5, 10, ...

متن کامل

Evaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures

The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...

متن کامل

Evaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures

The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...

متن کامل

Influence of the Isolator Characteristics on the Response of the Isolated Buildings in the Near-FaultEarthquakes

Seismic base isolation are devices that used to limit the human and material damage caused by an earthquake. This devices diffuse the energy induced at the time of the earthquake before being transferred to the structure.The base isolated structures when subjected to the near-fault eathquakes which contain long-period velocity pulses that may coincide with the period of base isolated structures...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015