Scatterogram: a method for outlining the body during lymphoscintigraphy without using external flood source
نویسندگان
چکیده
BACKGROUND We evaluated the feasibility of outlining the body with scattered photons using a low dose intradermal injection of the radiotracer. PATIENTS AND METHODS.: Sixty breast cancer patients were included into the study. 30 minutes post radiotracer injection static lymphoscintigraphy images were acquired using low energy high resolution collimator in anterior and lateral views. For patients with 2-day protocol another set of images was taken 20 hours post-injection. Two photopeaks were used during imaging: 1-Tc-99m (130-150 keV) and 2- Scatter photons (60-120). The fusion image of these two images was constructed by NM-NM fusion workflow of the workstation. The usual body outline of the patients was also acquired in 20 cases using the external flood source without moving the patients from their positions. RESULTS The early (30 minute image) scatterograms of the patients clearly showed the contour of the body. The 20 hour scatterograms were not as high quality as the corresponding early images. The constructed overlaid images showed the location of the axillary sentinel nodes and the body contours clearly for early scatterograms but not the delayed (20 hour) ones. The processing of the images for the reconstruction of overlaid scatterograms took the mean time of 10±5 seconds. CONCLUSIONS Imaging the scattered photons is feasible for the intradermal low dose injection of the radiotracers in order to outline the body contour. This imaging method does not increase the radiation exposure of the patients or operators and does not extend the time of imaging either.
منابع مشابه
Body outlining using Tc-99m filled flood source for lymphoscintigraphy imaging
Introduction: In the current study, we evaluated the feasibility of body outlining using Tc-99m filled flood source for lymphoscintigraphy imaging. Methods: 80 patients were included in the study. Sentinel node mapping was done using Tc-99m Antimony sulfide colloid. For outlining the body a Tc-99m filled flood source was used which was placed behind or lateral to t...
متن کاملTransmission Imaging in Lymphoscintigraphy with a 153Gd Flood Source.
UNLABELLED Lymphoscintigraphy uses intradermal or interstitial injections of (99m)Tc-labeled tracers to produce images of focal lymph nodes. Because there is little or no anatomic information in the (99m)Tc images, a (57)Co flood source is sometimes used to provide transmission data along with the emission data. The anatomic shadow from the transmission scan generally improves interpretation an...
متن کاملShielding studies on a total-body neutron activation facility
Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...
متن کاملTc-99m Phytate lymphoscintigraphy: An excellent method for diagnosis of underlying cause of chylous ascites
We reported a 14 months old boy referred for evaluation of chylous ascites to our nuclear medicine department. Tc-99m Phytate was injected subcutaneously in his calves and whole body images as well as abdominal SPECT were performed. The SPECT images could localize an area of several intestinal lymphangiomata in the abdominal region. The abnormal region was surgically resected and the patient as...
متن کاملطراحی وب سرویس مدیریت امدادرسانی پس از وقوع سیل با کمک اطلاعات جغرافیایی داوطلبانه (VGI) بر مبنای تکنولوژی متن باز
Accessibility to precise spatial and real time data plays a valuable role in the velocity and quality of flood relief operation and subsequently, scales the human and financial losses down. Flood real time data collection and processing, for instance, precise location and situation of flood victims may be a big challenge in Iran regarding the hardware facilities (such as high resolution aerial ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 45 شماره
صفحات -
تاریخ انتشار 2011