No influence of CO2 on stable isotope analyses of soil waters with off‐axis integrated cavity output spectroscopy (OA‐ICOS)

نویسندگان

  • Matthias Sprenger
  • Doerthe Tetzlaff
  • Chris Soulsby
چکیده

RATIONALE It was recently shown that the presence of CO2 affects the stable isotope (δ2 H and δ18 O values) analysis of water vapor via Wavelength-Scanned Cavity Ring-Down Spectroscopy. Here, we test how much CO2 is emitted from soil samples and if the CO2 in the headspace influences the isotope analysis with the direct equilibration method by Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS). METHODS The headspace above different amounts of sparkling water was sampled, and its stable isotopic composition (δ2 H and δ18 O values) and CO2 concentration were measured by direct equilibration and by gas chromatography, respectively. In addition, the headspace above soil samples was analyzed in the same way. Furthermore, the gravimetric water content and the loss on ignition were measured for the soil samples. RESULTS The experiment with the sparkling water showed that CO2 does not influence the stable isotope analysis by OA-ICOS. CO2 was emitted from the soil samples and correlated with the isotopic fractionation signal, but no causal relationship between the two was determined. Instead, the fractionation signal in pore water isotopes can be explained by soil evaporation and the CO2 can be related to soil moisture and organic matter which both enhance microbial activity. CONCLUSIONS We found, despite the high CO2 emissions from soil samples, no need for a post-correction of the pore water stable isotope analysis results, since there is no relation between CO2 concentrations and the stable isotope results of vapor samples obtained with OA-ICOS. © 2016 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design considerations in high-sensitivity off- axis integrated cavity output spectroscopy

Off-axis integrated cavity output spectroscopy (OA-ICOS) has generated much interest because it potentially allows highly sensitive field measurements with robust optical alignment. We discuss here design choices involved in design of an OA-ICOS instrument and how these choices impact instrument sensitivity, using as our example the design of the Harvard ICOS isotope instrument, which demonstra...

متن کامل

Combining Denitrifying Bacteria and Laser Spectroscopy for Isotopic Analyses (δ(15)N, δ(18)O) of Dissolved Nitrate.

We present a novel approach for nitrogen (δ(15)N) and oxygen (δ(18)O) isotopic analysis of nitrate in water based on the isotopic analysis of N2O produced from the conversion of NO3(-) by cultured denitrifying bacteria and off-axis integrated cavity output spectroscopy (OA-ICOS). The headspace N2O was manually injected into an OA-ICOS isotopic N2O laser analyzer through a syringe septum port. S...

متن کامل

Sensitivity enhancement in off-axis integrated cavity output spectroscopy.

We report on a detailed model of an improved three mirror off-axis integrated cavity output spectroscopy (OA-ICOS) setup, which re-injects the light reflected by the optical cavity. The model simulates the impact of design parameters on instrument sensitivity and can be used for any off-axis configuration. We demonstrate the application of this model for the real-time detection of ethylene with...

متن کامل

Measurement of δ18O, δ17O, and 17O-excess in water by off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry.

Stable isotopes of water have long been used to improve understanding of the hydrological cycle, catchment hydrology, and polar climate. Recently, there has been increasing interest in measurement and use of the less-abundant (17)O isotope in addition to (2)H and (18)O. Off-axis integrated cavity output spectroscopy (OA-ICOS) is demonstrated for accurate and precise measurements δ(18)O, δ(17)O,...

متن کامل

Optimum signal-to-noise ratio in off-axis integrated cavity output spectroscopy.

The signal-to-noise ratio (SNR) in off-axis integrated cavity output spectroscopy (OA-ICOS) is investigated and compared to direct absorption spectroscopy using multipass absorption cells [tunable diode laser absorption spectroscopy (TDLAS)]. Applying measured noise characteristics of a near-IR tunable diode laser and detector, it is shown that the optimum SNR is not generally reached at the hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2017