Electrophoresis using a constant potential across the separation field.

نویسندگان

  • G W Dike
  • F E Bew
چکیده

Reproducibility of electrophoretic runs depends on the maintenance of a smooth and constant voltage gradient within the supporting medium or separation chamber. Power packs to supply constant current or constant voltage as measured at the pack are readily available, but if such a pack is used with constant voltage, the proportion of the voltage drop available for the electrophoretic separation will be affected not only by changes in the resistance in the separation field, but also by changes in the external circuit, which will be certain to occur at the electrodes, separation membranes, or buffer reservoirs. For this reason, it is usual to work with constant current, since the voltage drop in the separation field will then be independent of the resistance changes in the external circuit. Brattsten (1955) demonstrated that the effect of temperature variation on migration velocity may be greater where constant voltage is used and recommended constant current. He was using a system without a supporting medium. Where supporting media are used there are many variables in addition to temperature. Under constant current conditions any change affecting the resistance within the supporting medium or separation chamber will cause a variation in the voltage gradient and consequently a lack of reproducibility from one run to another. In continuous electrophoresis, either with or without a supporting medium (as in the Elphor VaP apparatus), such variation leads to a reduction of the efficiency of separation. In micro-immunoelectrophoresis in agar the thickness of the agar and the buffer retention might vary from one batch of slides to the next. Supporting media, such as cellulose acetate, cellogel, or paper which have to be 'blotted' to remove surplus buffer, do not provide exactly reproducible conditions; ionic pile up at membranes or edges of supporting media will also affect reproducibility, and the heat produced during a run may cause progressive changes in supporting media. All these effects are even more pronounced with

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microfluidic preparative free-flow isoelectric focusing in a triangular channel: system development and characterization.

A preparative scale free-flow IEF device is developed and characterized with the aim of addressing needs of molecular biologists working with protein samples on the milligrams and milliliters scale. A triangular-shape separation channel facilitates the establishment of the pH gradient with a corresponding increase in separation efficiency and decrease in focusing time compared with that in a re...

متن کامل

Microfluidic Protein Separation by Free Flow Isoelectric Focusing

Disposable, inexpensive microfluidic devices have the potential to become a robust tool for proteomic research for separating and identifying proteins and protein complexes. In this work, a preparative scale free flow IEF isoelectric focusing (FFIEF) device was designed, investigated, and optimized. A constant electric field of up to 350V/cm was generated across the separation channel upon opti...

متن کامل

On-column conductivity detection in capillary-chip electrophoresis.

On-column conductivity detection in capillary-chip electrophoresis was achieved by actively coupling the high electric field with two sensing electrodes connected to the main capillary channel through two side detection channels. The principle of this concept was demonstrated by using a glass chip with a separation channel incorporating two double-Ts. One double-T was used for sample introducti...

متن کامل

Study of Parameters Affecting Separation Bubble Size in High Speed Flows using k-ω Turbulence Model

Shock waves generated at different parts of vehicle interact with the boundary layer over the surface at high Mach flows. The adverse pressure gradient across strong shock wave causes the flow to separate and peak loads are generated at separation and reattachment points. The size of separation bubble in the shock boundary layer interaction flows depends on various parameters. Reynolds-averaged...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 1967