Biomechanical Evaluation of Four Methods for Internal Fixation of Comminuted Subtrochanteric Fractures

نویسندگان

  • Jie Wang
  • Jian-xiong Ma
  • Hao-bo Jia
  • Yang Chen
  • Yang Yang
  • Xin-long Ma
چکیده

Subtrochanteric fractures are common and result in significant morbidity and mortality. Various kinds of implants have been used to fix it. The aim of this study was to compare the biomechanical performance of PFN, DHS, DCS, and the PFLP in the treatment of subtrochanteric comminuted fractures.A total of 32 antiseptic human femurs from 16 donors were randomly allocated to 4 groups for fixation with PFN, DHS, DCS, and PFLP. A 2-cm cylindrical bone fragment was removed 1 cm below the lesser trochanter to simulate OTA/AO 32-C3.2 post instrumentation fracture. All specimens in single-leg stance situation were preloaded 5 times at 100 N in the axial direction to eliminate the time effect of relaxation and settling, followed by cyclic testing at a rate of 1 Hz with stepwise increasing load. Keeping the valley load at a constant level of 100 N during the entire cyclic test, the peak load, starting at 200 N, was increased by 100 N at 300-cycle steps until a maximum of 1500 cycles or until failure of the bone-implant construct occurred. Each specimen was kept unloaded under 100 N compression for 30 minutes between the 300-cycle steps.Femoral head displacement after 1500 cycles was 1.09 mm ± 0.13 for PFN, 1.78 mm ± 0.25 for DHS, 2.63 mm ± 0.46 for DCS, and 2.26 mm ± 0.16 for PFLP, with significant difference between any 2 implants (P < 0.01). The required load to reach 1-mm femoral head displacement was 563.04 N ± 158.34 for PFN, 485.73 N ± 147.27 for DHS, 258.44 N ± 97.23 for DCS, and 332.68 N ± 100.34 for PFLP. Significant differences were detected between any 2 implants (P < 0.001), except between DCS and PFLP and between DHS and PFN. The number of cycles until 1-mm femoral head displacement was 1458 ± 277 for PFN, 908 ± 184 for DHS, 369 ± 116 for DCS, and 603 ± 162 for PFLP. Significant differences were detected between any 2 implants (P < 0.01), except between DCS and PFLP.From biomechanical point of view, comminuted subtrochanteric fractures OTA/AO 32-C3.2 revealed in the current test setup highest fixation strength with PFN, followed by DHS, PFLP, and DCS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تکنیک صفحه‌گذاری بیولوژیک در شکستگی‌های چند قطعه‌ای ساب‌تروکانتریک استخوان ران

Background: Comminuted subtrochanteric fractures have been a challenge for orthopedic surgeons in terms of appropriate reduction and stable fixation. Numerous methods have been used for the fixation of comminuted subtrochanteric fractures among which some are accompanied with technical difficulties and complications of their own. Regarding the results of previous studies, we decided to evaluate...

متن کامل

Closed treatment of subtrochanteric fractures of the femur in a modified cast-brace.

We studied a series of fifteen consecutive subtrochanteric fractures treated in a long quadrilateral cast-brace with a pelvic band. Patients with severely comminuted fractures in which stability cannot be obtained by internal fixation, as well as those with open fractures, are considered candidates for such treatment. Treatment with preliminary traction followed by a ambulatory cast-brace with ...

متن کامل

Clinical Results of Complex Subtrochanteric Femoral Fractures with Long Cephalomedullary Hip Nail

PURPOSE Good results of the cephalomedullary nails have been reported in proximal femoral fractures recently. Based on length of nails and shape of screws fixed in a femoral head for proximal fragment fixation, the proper nail length was in dispute. The purpose of this study was to evaluate the clinical and radiological results of a long cephalomedullary hip nail for the treatment of comminuted...

متن کامل

Treatment of comminuted subtrochanteric fractures by dynamic hip screw.

Twenty four cases of fracture of the proximal femoral shaft treated with dynamic hip screw fixation are included. All had severe comminution with subtrochanteric extensions. Dynamic hip screw provided stable osteosynthesis and helped to achieve bone union within 18 weeks in 19 of 21 followed-up cases. The anatomical configuration of the femur was maintained with minimal limb length discrepancy ...

متن کامل

Biological plate fixation of comminuted subtrochanteric fractures with the Dynamic Condylar Screw: a clinical study.

Subtrochanteric fractures are fraught with anatomical, biological and biomechanical challenges which account for an increased incidence of nonunion and malunion. We retrospectively assessed the results achieved in 40 patients with a mean age of 36 years who were treated with biological plating using a Dynamic Condylar Screw for comminuted subtrochanteric femoral fractures between January 2004 t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016