Design and Deployment of a Knee Prosthesis Emulator System

نویسندگان

  • James Gabriel
  • Steven H. Collins
چکیده

Robotic knee prostheses have been improving, thereby raising the quality of life for above knee amputees. To continue this progression requires robust and versatile research tools to study the subtle biomechanical interactions between the human and the prostheses. To serve this purpose, we have created a tethered knee prosthesis with flexion and extension torque control. To reduce weight and complexity, the flexion motor, extension motor, and control hardware have been moved offbody. Power from the motors is transmitted to the prosthesis by means of bowden cables, and measurements of state are sent back through this tether. The resulting knee prosthesis weights only 0.8 kg. Benchtop tests were conducted to calibrate the strain gauges which measure torque, find the step response rise-time of the system, and find the closed loop torque bandwidths of each motor. The RMS error for flexion torque was 0.27 N·m and extension torque was 0.54 N·m . The 90% rise time was 14.3 ± 1.1 ms for flexion, and 11.6±1.0 ms for extension. The bandwidth was 28.0 Hz for flexion and 27.2 Hz for extension. Such high bandwidths and peak torques make this emulator suited for studying normal walking and running gaits as well as stumble recovery. This versatile system can also be used to design and test new control strategies for stumble recovery, walking, and running. This can lead to improved balance, metabolics, and quality of life for those with above knee amputations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Controller Design for Swing Phase of a Single Axis Above-Knee Prosthesis

In this research we design a passive controller for an above knee prosthesis. The controller is a linear spring and damper for swing phase motion, parameters of which determined via optimization of adjustment of the prosthesis shank motion with a desired shank angle trajectory comes from experimental data. In this way, we exerted a certain thigh motion, hip movement included, into the system as...

متن کامل

Design of an Agonist-Antagonist Knee Prosthesis for Experiments in Human Locomotion

We previously developed an ankle-foot prosthesis emulator with exceptional versatility [1]. It is lightweight, capable of producing large torque and power, and can quickly change behaviors [2]. However, it cannot fully address the needs of trans-femoral amputees. In the commercial market there are many active knees such as the Ottobock C-leg and Össur Power Knee. These are successful products, ...

متن کامل

Design and Evaluation of a Magnetorheological Damper Based Prosthetic Knee

In this work, a magnetorheological (MR) damper based above-knee prosthesis is design and evaluated based on its performance in swing phase and in stance phase. Initially, a dynamic system model for swing phase of a prosthetic leg incorporating a single-axis knee with ideal MR damper was built. The dynamic properties of the damper are represented with Bingham parametric model. From Bingham model...

متن کامل

Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach

Introduction: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian L...

متن کامل

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016