Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: the Third Sonography Outcomes Assessment Program (SOAP-3) Trial.
نویسندگان
چکیده
CONTEXT A 2001 Agency for Healthcare Research and Quality Evidence Report on patient safety addressed point-of-care limited ultrasonography guidance for central venous cannulation and strongly recommended real-time, dynamic guidance for all central cannulas. However, on the basis of one limited study, the report dismissed static assistance, a "quick look" with ultrasound to confirm vein location before preparing the sterile field, as unhelpful. OBJECTIVE The objective of this trial was to compare the overall success rate of central cannula placement with use of dynamic ultrasound (D), static ultrasound (S), and anatomical landmarks (LM). DESIGN AND SETTING A concealed, randomized, controlled, clinical trial conducted from September 2003 to February 2004 in a U.S. urban teaching hospital. PATIENTS Two-hundred one patients undergoing internal jugular vein central venous cannulation. INTERVENTIONS Patients were randomly assigned to three groups: 60 to D, 72 to S, and 69 to LM. An iLook25 SonoSite was used for all imaging. MEASUREMENTS AND MAIN RESULTS Cannulation success, first-attempt success, and number of attempts were noted. Other measures were vein size and clarity of LM. Results, controlled for pretest difficulty assessment, are stated as odds improvement (95% confidence interval) over LM for D and S. D had an odds 53.5 (6.6-440) times higher for success than LM. S had an odds 3 (1.3-7) times higher for success than LM. The unadjusted success rates were 98%, 82%, and 64% for D, S, and LM. For first-attempt success, D had an odds 5.8 (2.7-13) times higher for first success than LM, and S had an odds 3.4 (1.6-7.2) times higher for first success than LM. The unadjusted first-attempt success rates were 62%, 50%, and 23% for D, S, and LM. CONCLUSIONS Ultrasound assistance was superior to LM techniques. D outperformed S but may require more training and personnel. All central cannula placement should be conducted with ultrasound assistance. The 2001 Agency for Healthcare Research and Quality Evidence Report dismissing static assistance was incorrect.
منابع مشابه
Effectiveness of Tailored Care Intervention Program on Biochemical Outcomes of Patients with Diabetes in Indonesia: A Randomized Controlled Trial
Background: Although people with diabetes have common problems, their educational needs may be different and they all have the right to participate in the planning and implementation of individual or group health care programs. Meanwhile, there are no proper care interventions for diabetic patients in Indonesia. Therefore, the aim of this study was to evaluate the efficacy of a tailored care in...
متن کاملRandomized controlled clinical trial of point-of-care, limited ultrasonography for trauma in the emergency department: the first sonography outcomes assessment program trial.
STUDY OBJECTIVE Annually, 38 million people are evaluated for trauma, the leading cause of death in persons younger than 45 years. The primary objective is to assess whether using a protocol inclusive of point-of-care, limited ultrasonography (PLUS), compared to usual care (control), among patients presenting to the emergency department (ED) with suspected torso trauma decreased time to operati...
متن کاملEffect of Statin Treatment on COVID-19 Patients’ Outcomes: A Randomized Double-blind Controlled Clinical Trial
Background: Statins may be protective against viral infection and have been suggested for the treatment of coronavirus disease 2019 (COVID-19). Objective: In this study, we aimed to evaluate the effect of atorvastatin on COVID-19 patients. Methods: Our study is a randomized double-blind controlled clinical trial that constitutes a population of COVID-19 patients admitted to Bu-Ali Sina Hospi...
متن کاملComparative clinical assessment of two nasolabial hyaluronic acid fillers: A double-blind, randomized controlled trial
Background: Various fillers have been used for the correction of nasolabial folds. This study investigated the efficacy and safety assessment of two hyaluronic acid (HA) fillers on moderate nasolabial folds. Methods: This study randomized 10 volunteers, aged 35 to 49 years, with moderate nasolabial folds. Volunteers received injections of HA A and HA B gels into the right or left skin folds. Th...
متن کاملGuidance and examination by ultrasound versus landmark and radiographic method for placement of subclavian central venous catheters: study protocol for a randomized controlled trial
BACKGROUND Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 33 8 شماره
صفحات -
تاریخ انتشار 2005