Influence of sensor ingestion timing on consistency of temperature measures.

نویسندگان

  • Daniel A Goodman
  • Robert W Kenefick
  • Bruce S Cadarette
  • Samuel N Cheuvront
چکیده

PURPOSE The validity and the reliability of using intestinal temperature (T int) via ingestible temperature sensors (ITS) to measure core body temperature have been demonstrated. However, the effect of elapsed time between ITS ingestion and T int measurement has not been thoroughly studied. METHODS Eight volunteers (six men and two women) swallowed ITS 5 h (ITS-5) and 29 h (ITS-29) before 4 h of varying intensity activity. T int was measured simultaneously from both ITS, and T int differences between the ITS-5 and the ITS-29 over the 4 h of activity were plotted and compared relative to a meaningful threshold of acceptance (+/-0.25 degrees C). The percentage of time in which the differences between paired ITS (ITS-5 vs ITS-29) were greater than or less than the threshold of acceptance was calculated. RESULTS T int values showed no systematic bias, were normally distributed, and ranged from 36.94 degrees C to 39.24 degrees C. The maximum T int difference between paired ITS was 0.83 degrees C with a minimum difference of 0.00 degrees C. The typical magnitude of the differences (SE of the estimate) was 0.24 degrees C, and these differences were uniform across the entire range of observed temperatures. Paired T int measures fell outside of the threshold of acceptance 43.8% of the time during the 4 h of activity. CONCLUSIONS The differences between ITS-5 and ITS-29 were larger than the threshold of acceptance during a substantial portion of the observed 4-h activity period. Ingesting an ITS more than 5 h before activity will not completely eliminate confounding factors but may improve accuracy and consistency of core body temperature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of aging temperature on phase transformation and mechanical behavior of NiTi thin films deposited by magnetron sputtering technique

In this study, NiTi thin films were deposited on the glass and NaCl substrates by means of magnetron sputtering method. The influence of aging temperature, over the range 300-500 oC, on phase transformation and mechanical properties of the sputtered NiTi thin films were studied by differential scanning calorimetry (DSC) and nano-indentation assay, respectively. The DSC curves showed that the ag...

متن کامل

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

Preparation and Application of Al3+ - Sensor Based On (2Z) — Methyl 2 — ((z) (p-tolylimino) -3-Ethyl —4-0xothiazolidin —5— Ylidene Acetate in PVC Matrix

Al3+-Potentiometric sensor, based on (2Z) -methyl 2- ((z) (p-tolylimino)-3-ethyl -4-oxothiazolidin -5- ylidene) Acetate (MTEOY) as a neutral ionophore, was successfully developed for the detectionof Al3+ in aqueous solutions. The electrode responds to Al3+ ion with a sensitivity of 19.8 ± 0.1 mV/decade over the range 1.0 x 10-8- 1.0 x 10-1 mol LT' and in a pH range of 3.0-9.0. The electrodeshow...

متن کامل

Influence of varying timing angle on performance of an SI engine: An experimental and numerical study

Engine performance depends on two main factors of engine speed and ignition time. Ignition timing can affect engine life, fuel economy and engine power. In this paper, to study engine performance of Peugeot 206 TU3A with comparison ratio of 10.5:1 and displacement of 1361CC in MATLAB software, a two-zone burned/unburned model with the fuel burning rate described by aWiebe function was used for ...

متن کامل

Experimental investigations on a pre-chamber spark plug with variable heat range by integrating a controlled hot surface

In gasoline engines, pre-chamber spark ignition systems are used to achieve high efficiency and low NOx emissions when operating under lean conditions. While a cold pre-chamber spark plug can lead to misfiring and flame quenching under cold start or part load operation, a hot pre-chamber can result in uncontrolled pre-ignition phenomena under full load operation. This paper presents an approach...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicine and science in sports and exercise

دوره 41 3  شماره 

صفحات  -

تاریخ انتشار 2009