Clustering-Based Linear Least Square Fitting Method for Generation of Parametric Images in Dynamic FDG PET Studies
نویسندگان
چکیده
Parametric images generated from dynamic positron emission tomography (PET) studies are useful for presenting functional/biological information in the 3-dimensional space, but usually suffer from their high sensitivity to image noise. To improve the quality of these images, we proposed in this study a modified linear least square (LLS) fitting method named cLLS that incorporates a clustering-based spatial constraint for generation of parametric images from dynamic PET data of high noise levels. In this method, the combination of K-means and hierarchical cluster analysis was used to classify dynamic PET data. Compared with conventional LLS, cLLS can achieve high statistical reliability in the generated parametric images without incurring a high computational burden. The effectiveness of the method was demonstrated both with computer simulation and with a human brain dynamic FDG PET study. The cLLS method is expected to be useful for generation of parametric images from dynamic FDG PET study.
منابع مشابه
Comparison of parametric FBP and OS-EM reconstruction algorithm images for PET dynamic study.
An ordered subsets expectation maximization (OS-EM) algorithm is used for image reconstruction to suppress image noise and to make non-negative value images. We have applied OS-EM to a digital brain phantom and to human brain 18F-FDG PET kinetic studies to generate parametric images. A 45 min dynamic scan was performed starting injection of FDG with a 2D PET scanner. The images were reconstruct...
متن کاملImproved parametric image generation using spatial-temporal analysis of dynamic PET studies.
The value of parametric images that represent both spatial distribution and quantification of the physiological parameters of tracer kinetics has long been recognized. However, the inherent high noise level of pixel kinetics of dynamic PET makes it unsuitable to generate parametric images of the microparameters of tracer kinetic model by conventional weighted nonlinear least squares (WNLS) fitt...
متن کاملAutomated Movement Correction for Dynamic PET/CT Images: Evaluation with Phantom and Patient Data
Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedu...
متن کاملComparison of Algorithms for Generating Parametric Image of Cerebral Blood Flow Using H2 O Positron Emission Tomography
Purpose: To obtain regional blood flow and tissue-blood partition coefficient with time-activity curves from H2 O PET, fitting of some parameters in the Kety model is conventionally accomplished by nonlinear least squares (NLS) analysis. However, NLS requires considerable compuation time then is impractical for pixel-by-pixel analysis to generate parametric images of these parameters. In this s...
متن کاملQuantitative approaches of dynamic FDG-PET and PET/CT studies (dPET/CT) for the evaluation of oncological patients
OBJECTIVES The use of dynamic positron emission tomography/computed tomography (dPET/CT) studies with [18F]deoxyglucose (FDG) in oncological patients is limited and primarily confined to research protocols. A more widespread application is, however, desirable, and may help to assess small therapeutic effects early after therapy as well as to differentiate borderline differences between tumour a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International Journal of Biomedical Imaging
دوره 2007 شماره
صفحات -
تاریخ انتشار 2007