Vascular closure device failure: frequency and implications: a propensity-matched analysis.

نویسندگان

  • Sripal Bangalore
  • Nipun Arora
  • Frederic S Resnic
چکیده

BACKGROUND Vascular closure devices (VCDs) are effective in reducing the time to ambulation for patients undergoing cardiac catheterization procedures and in reducing the risk of vascular complications in selected patient cohorts. However, the frequency and consequence of failure of VCDs is not well defined. METHODS AND RESULTS From a prospective registry of consecutive patients undergoing cardiac catheterization at our center, 9823 patients who received either a collagen plug-based (Angio-Seal) or a suture-based (Perclose) VCD were selected for the study. VCD failure was defined as unsuccessful deployment or failure to achieve hemostasis. Major vascular complication was defined as any retroperitoneal hemorrhage, limb ischemia, or any surgical repair. Minor vascular complication was defined as any groin bleeding, hematoma (> or = 5 cm), pseudoaneurysm, or arteriovenous fistula. Any vascular complication was defined as either a major or minor vascular complication. Among the 9823 patients in the study, VCD failed in 268 patients (2.7%; 2.3% diagnostic versus 3.0% percutaneous coronary intervention; P=0.029). Patients with VCD failure had significantly increased risk of any (6.7% versus 1.4%; P<0.0001), major (1.9% versus 0.6%; P=0.006), or minor (6.0% versus 1.1%; P<0.0001) vascular complication compared with the group with successful deployment of VCD. The increased risk of vascular complication was unchanged in a propensity score-matched cohort. CONCLUSIONS In contemporary practice, VCD failure is rare, but when it does fail, it is associated with a significant increase in the risk of vascular complications. Patients with VCD failure should be closely monitored.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The data extraction and longitudinal trend analysis network study of distributed automated postmarket cardiovascular device safety surveillance.

BACKGROUND Current approaches for postmarket medical device safety surveillance are limited in their ability to produce timely and accurate assessments of adverse event rates. METHODS AND RESULTS The Data Extraction and Longitudinal Trend Analysis (DELTA) network study was a multicenter prospective observational study designed to evaluate the safety of devices used during percutaneous coronar...

متن کامل

Propensity-matched comparison between Direct Flow Medical, Medtronic Corevalve, and Edwards Sapien XT prostheses: Device success, thirty-day safety, and mortality.

AIMS To compare 30-day performance of three different type of transcatheter aortic valve implantation (TAVI) prosthesis: Direct Flow Medical (DFM), Medtronic Corevalve (MCV), and Edwards Sapien XT (ES). METHODS AND RESULTS Forty consecutive patients treated with DFM for severe aortic stenosis were matched to an equal sample of patients undergoing TAVI with MCV and ES (1:1:1 propensity score-m...

متن کامل

Long-term propensity score-matched comparison of percutaneous closure of patent foramen ovale with medical treatment after paradoxical embolism.

BACKGROUND Patients with ischemic stroke or transient ischemic attack presumably related to patent foramen ovale (PFO) are at risk for recurrent cerebrovascular events. Differences in long-term clinical outcome were investigated among patients with percutaneous PFO closure and those who received medical treatment. METHODS AND RESULTS Between 1994 and 2000, 308 consecutive patients with cerebr...

متن کامل

A propensity score-matched comparison between Cardia and Amplatzer PFO closure devices - insights from the SOLUTION registry (Swiss percutaneOus patent foramen ovale cLosUre in recurrent clinical events prevenTION).

AIMS To compare clinical outcome of Amplatzer PFO (APFO) to Cardia PFO (CPFO) occluder. Percutaneous patent foramen ovale (PFO) closure prevents stroke recurrence in stroke due to paradoxical embolism. METHODS AND RESULTS The primary endpoint was a composite of stroke, TIA, or peripheral embolism at follow-up. The secondary endpoint was residual shunt. Outcome was compared among 934 (APFO: 71...

متن کامل

Rare Adverse Event Monitoring of Medical Devices with the Use of an Automated Surveillance Tool

Prospective outcomes surveillance using population level data allows for statistical methodologies and confounder adjustment not supported by the FDA's current monitoring system. We explored propensity score matching integrated into an automated surveillance tool as a method for confounder adjustment in an observational cohort. The application analyzed all patients undergoing PCI via femoral ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 2 6  شماره 

صفحات  -

تاریخ انتشار 2009