Transmural metabolic heterogeneity at high cardiac work states.
نویسندگان
چکیده
This study compared the transmural distribution of high-energy phosphate (HEP) depletion during oxidative stress induced by pacing- and dobutamine-induced tachycardia in myocardium perfused by a flow-limiting coronary stenosis. Myocardial blood flow (MBF) was measured with radioactive microspheres. Creatine phosphate (CrP), ATP, and Pi were measured with transmurally localized 31P NMR spectroscopy. In normal dogs a hydraulic occluder was used to produce a left anterior descending coronary artery stenosis, which maintained constant flow measured with a Doppler probe. Tachycardia was induced by rapid pacing (200 beats/min, n = 11) or by dobutamine infusion (20 μg ⋅ kg-1 ⋅ min-1 iv, n = 13) to produce a similar heart rate. In the presence of stenosis, pacing and dobutamine caused similar reductions of subendocardial (Endo)-to-subepicardial (Epi) MBF ratios (0.66 ± 0.06 vs. 0.63 ± 0.08, respectively). Stenosis plus pacing caused a decrease of the CrP-to-ATP ratio (CrP/ATP) in Endo from 2.00 ± 0.07 to 1.65 ± 0.08 ( P < 0.05) with no significant change in Epi. Stenosis plus dobutamine caused HEP changes across the left ventricular wall, which were most marked in the outer myocardial layer (Epi CrP/ATP decreased from 2.33 ± 0.11 to 1.67 ± 0.12; Endo CrP/ATP decreased from 1.99 ± 0.09 to 1.64 ± 0.12). Thus HEP changes during oxidative stress that are produced by pacing parallel the pattern of hypoperfusion and are most severe in the subendocardium. In contrast, in response to inotropic stimulation, the transmural metabolic changes did not correspond to the pattern of the hypoperfusion.
منابع مشابه
Transmural distribution of metabolic abnormalities and glycolytic activity during dobutamine-induced demand ischemia.
The heterogeneity across the left ventricular wall is characterized by higher rates of oxygen consumption, systolic thickening fraction, myocardial perfusion, and lower energetic state in the subendocardial layers (ENDO). During dobutamine stimulation-induced demand ischemia, the transmural distribution of energy demand and metabolic markers of ischemia are not known. In this study, hemodynamic...
متن کاملDependence of phase-2 reentry and repolarization dispersion on epicardial and transmural ionic heterogeneity: a simulation study.
AIMS Phase-2 reentry (P2R) is a local arrhythmogenic phenomenon where electrotonic current propagates from a spike-and-dome action potential region to re-excite a loss-of-dome action potential region. While ionic heterogeneity has been shown to underlie P2R within the epicardium and has been hypothesized to occur transmurally, we are unaware of any study that has investigated the effects of com...
متن کاملTransmural heterogeneity of action potentials and I to1 in myocytes isolated from the human right ventricle.
Limited information is available about transmural heterogeneity in cardiac electrophysiology in man. The present study was designed to evaluate heterogeneity of cardiac action potential (AP), transient outward K+ current ( I to1) and inwardly rectifying K+ current ( I K1) in human right ventricle. AP and membrane currents were recorded using whole cell current- and voltage-clamp techniques in m...
متن کاملTransmural heterogeneity of Na+-Ca2+ exchange: evidence for differential expression in normal and failing hearts.
Spatial electrical heterogeneity has a profound effect on normal cardiac electrophysiology and genesis of cardiac arrhythmias in diseased hearts. The Na+-Ca2+ exchanger (NCX) is a key linker, through Ca2+ signaling, between contractility and arrhythmias. Here we characterize the differential transmural expression of NCX in normal and rapid pacing-induced failing canine hearts. Significant trans...
متن کاملIncreased heterogeneity of ventricular repolarization in myotonic dystrophy type 1 population
Sudden cardiac death in myotonic dystrophy type I (DM1) patients can be attributed to atrioventricular blocks as far as to the development of life-threatening arrhythmias which occur even in hearts with normal left ventricular systolic and diastolic function. Heterogeneity of ventricular repolarization is considered to provide an electrophysiological substrate for malignant arrhythmias. QTc dis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 277 1 شماره
صفحات -
تاریخ انتشار 1999