Timing of Fast Scintillators using Digitizers
نویسندگان
چکیده
Recently, FPGA based digitizers have found attractive applications in signal processing for complex detector arrays in nuclear physics [1]. In the fast digitizers, a flash ADC directly samples and stores the PMT output of scintillation detectors. Digital Signal Processing (DSP) techniques are used to extract the energy and timing information of the acquired signal. DSP not only reduces requirement of electronics units and cabling, but also eliminates temperature related drifts to a large extent. The jitter and walk introduced by the discriminator in an analog chain can be avoided by using digital timing techniques.
منابع مشابه
Investigation of Lanthanum Scintillators for 3-D PET
The main thrust for this work is the investigation and design of a positron emission tomography (PET) scanner based on new Lanthanum Halide scintillators. In three–dimensional (3-D) PET the major limitations are scanner dead-time and ability to reject randoms and scatter. Therefore, to reach the full potential of 3-D PET requires a scintillator with good timing resolution and good energy resolu...
متن کاملUltra-Fast Timing with Plastic Scintillators
As precursor to HISPEC, the upcoming PreSPEC campaign incorporates the commissioning of the first version of the LYCCA (Lund-York-Cologne-CAlorimeter) detector system called LYCCA-0. The LYCCA detector is a Time-of-Flight (ToF), ∆E, E set-up designed to unambigiously identify nuclear reaction products by their mass A, and charge Z . For this to be possible up to masses around A = 100, the total...
متن کاملTOF-PET detector concept based on organic scintillators
In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of th...
متن کاملThin scintillators for ultrafast hard X-ray imaging
A multilayer thin-scintillator concept is described for ultrafast imaging. The individual layer thickness is determined by the spatial resolution and light attenuation length, the number of layers is determined by the overall efficiency. By coating the scintillators with a high quantum-efficiency photocathode, single X-ray photon detection can be achieved using fast scintillators with low light...
متن کاملUsing Timing Data to Measure Signal Attenuation in the G Scintillators
In this research project cosmic ray data will be used to measure signal attenuation and check the geometrical efficiency of the trigger along the G scintillators. For an equal amount of energy lost in the scintillator, the amplitude of the detected signal varies as the hit location along the scintillator varies. Particles that strike the scintillators cause the material to emit photons. The int...