Anatomic and hemodynamic correlations in carotid artery stenosis.

نویسندگان

  • J A Deweese
  • A G May
  • E O Lipchik
  • C G Rob
چکیده

A natomic and Hemodynamic Correlations in Carotid Artery Stenosis • Pressures were measured in the carotid arteries of 61 patients proximal and distal to atherosclerotic plaques which were carefully studied by angiography and anatomical dissection. (1) An atherosclerotic plaque causing a constriction of less than 47% luminal diameter leaving a lumen greater than 3.0 mm in diameter never caused pressure drops of greater than 10 mm Hg. Stenoses of greater than 63% luminal diameter leaving lumens less than 1.0 mm in diameter always caused pressure drops. (2) Atherosclerotic plaques producing defects which narrowed the lumen fell into a distinct pattern: (a) Type 1 lesions—This basic lesion filled the bulb of the internal carotid artery near its origin, causing a 1 to 2 cm smooth elliptical encroachment on the lumen. (b) Type 2 lesions—Short localized areas of thickening in addition to the basic lesion caused bar-like defects of the lumen at the origin of the internal carotid artery or near the distal end of the lesion. (c) Type 3 lesions—Multiple bar-like defects were sometimes seen. (d) Type 4 lesions—The areas of increased thickening of the lesion were sometimes quite narrow, producing diaphragm-like defects on the lumen. Although theoretically these various types of stenoses should produce different hemodynamic changes, insufficient numbers of observations were made to corroborate these presumptions. (3) Angiograms in general mimicked the gross appearance of the plaques and predicted the actual degree of stenosis produced but did not identify many diaphragm defects, ulcerations, or small thrombi. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

Candida patients in a Jorjani center in Shahid Mohammadi Hospital of carotid Doppler sonnograghy findings in coronary artery Bypas grafting Bandar Abbas

Introduction: Nowadays caotid Dopplers sonography is gold standard for carotid artery screening in coronary aetery bypass grafting (CABG) candidates. This study was carried out in an angioplasty center in southern seaport in Iran to assesss theprevalence of artery stenosis and correlation of the atherosclerosis risk factor with the rate of artery stensis, and nence to define the high risk group...

متن کامل

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 1 3  شماره 

صفحات  -

تاریخ انتشار 1970