Assessment of intra- and inter-ventricular cardiac dyssynchrony in patients with repaired Tetralogy of Fallot: a cardiac magnetic resonance study

نویسندگان

  • Linyuan Jing
  • Christopher M Haggerty
  • Jonathan D Suever
  • Ashwin Prakash
  • Frank Cecchin
  • Oskar Skrinjar
  • Tal Geva
  • Andrew J Powell
  • Brandon K Fornwalt
چکیده

Methods 30 patients with repaired TOF (age 28 ± 16, 46% female) and 17 healthy controls (age 29 ± 7, 12% female) underwent cine CMR. Patients were imaged twice to assess inter-test reproducibility. Circumferential strain vs time curves were generated with a custom feature tracking algorithm for 12 LV and 12 RV segments in 4-7 slices encompassing the ventricles. For each segment, the temporal offset (TO) of the strain curve relative to a global reference curve derived from the controls was calculated and expressed as a percent of the cardiac cycle. The intra-ventricular dyssynchrony index (DI) for each ventricle was computed as the standard deviation (SD) of the TOs (more dyssynchrony increases the SD). The inter-ventricular DI was calculated as the difference in median RV and median LV TOs. Regional dyssynchrony was quantified in 3 LV (septum, infero-lateral and antero-lateral wall) and 3 RV (septum, sinus, outflow tract) regions using median TOs. Results Compared to controls, patients with repaired TOF had a greater LV, RV and inter-ventricular DI (Figure 1). The greater inter-ventricular delay in the patients was primarily due to a global delay in RV contraction with the RV contracting 4.9 ± 3.5% later than the LV in patients vs 1.4 ± 3.2% earlier in controls (Figure 1). Median TOs were similar in the three LV regions between patients and controls, but all three RV regions were significantly delayed in patients compared to the controls. Contraction patterns in the RV were also distinct: in controls, the earliest contraction was seen in the outflow tract; in patients, contraction occurred first in the septum and last in the outflow tract (Figure 2). Inter-test reproducibility for the three DIs was good with all coefficients of variation <20%. QRS duration was prolonged in the patients compared to the controls (150 ± 27 ms vs 85 ± 8 ms, p < 0.001). However, QRS duration was not correlated with any of the DIs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Inter-study variability in CMR measurements of right ventricular volume, mass and ejection fraction in tetralogy of fallot: a prospective observational study

Background Cardiac MRI (CMR) is commonly used for serial monitoring of right ventricular (RV) size and function in patients with repaired tetralogy of Fallot (TOF). However, the inter-study variability of these measurements is not known, which hinders accurate interpretation of serial changes. In this study we prospectively assessed the inter-study variability of CMR measurements of RV size and...

متن کامل

Main indications and long-term outcomes of reoperation after initial repair of tetralogy of Fallot

Background and Objective: The aim of this study was to analyze our indications, surgical procedures, and clinical outcomes of patients undergoing reoperation after surgical correction of tetralogy of Fallot (TOF). Methods: Thirty seven consecutive patients who underwent reoperation late after intra-cardiac repair of TOF within a period of 10 years were assessed. Results: The most co...

متن کامل

Association of ventricular dyssynchrony and strain with cardiac function in patients with repaired tetralogy of Fallot

Background Patients with repaired tetralogy of Fallot (rTOF) have impairments in cardiac mechanics (strain and dyssynchrony). However, the relationship between cardiac strain, dyssynchrony, and cardiac function (measured by ejection fraction) in patients with rTOF has not been explored comprehensively in a large population. We hypothesized that measures of cardiac mechanics are associated with ...

متن کامل

Assessment of right ventricular function by treadmill exercise stress cardiovascular magnetic resonance in patients with repaired tetralogy of Fallot

Background Cardiac MR (CMR) is considered the gold standard to assess right ventricular (RV) function in different scenarios, including cases of congenital heart disease. Moreover, an MR-compatible treadmill coupled with Real Time (RT) CMR has been developed for stress testing, and may be an optimal choice in this setting. The aims of this study were to determine the feasibility and accuracy of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014