Acoustic simulations of cochlear implants in human and machine hearing research

نویسنده

  • Cong-Thanh Do
چکیده

In this chapter, we review conventional uses of acoustic simulations in cochlear implants research and introduce novel applications of acoustic simulations of cochlear implants, both in cochlear implants research and in other domains, such as automatic speech recognition (ASR) research. In this respect, the first part of the chapter is dedicated in reviewing the conventional applications of acoustic simulations in cochlear implants research. Actually, acoustic simulations are used in two typical applications in the research of cochlear implants. In the first one, acoustic simulations of cochlear implants are used to define how many independent channels are needed in order to achieve high levels of speech understanding? (Loizou et al., 1999). In fact, it is difficult to answer this question basing on the results of subjective tests performed by cochlear implant users, since their performance might be affected by many cofounding factors (e.g. number of surviving ganglion cells). For example, if a cochlear implant user obtains poor auditory performance using 4 channels of stimulation, the rationale might be that 4 stimulating channels are not enough but it could probably be blamed for the lack of surviving ganglion cells near the stimulating electrodes (Loizou et al., 1999). Using acoustic simulations can help in separating the rationale coming from the lack of surviving ganglion cells. The second application of acoustic simulations in cochlear implants research is for determining the effect of electrode insertion depth on speech understanding. In cochlear implantation, electrode arrays are inserted only partially to the cochlea, typically 22-30 mm, depending on the state of the cochlea. Acoustic simulations of cochlear implants could be used to simulate the effect of depth of electrode insertion on identification accuracy. In this respect, normal hearing listeners performed identification tasks with an acoustic simulation of cochlear implant whose electrodes are separated by 4 mm (Dorman et al., 1997). Insertion depth was simulated by outputting sine waves from each channel of the processor at a frequency determined by the cochlear place of electrode inserted 22-25 mm into the cochlea, through the Greenwood’s frequency-to-place equation (Greenwood, 1990). The results indicated that simulated insertion depth had a significant effect on speech identification performance (Dorman et al., 1997).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Speech Perception in Children with Cochlear Implants

Cochlear implants provide access to the speech signal in children with hearing loss that often cannot benefit from acoustic hearing aids. However, despite the numerous positive results in pediatric cochlear implantation, published data still indicated a wide range of performance among implant recipients. Hence, a need to study the possible variables that can affect performance, could account fo...

متن کامل

Emotional Perception of Music in Children with Unilateral Cochlear Implants

Introduction: Cochlear implantation (CI) improves language skills among children with hearing loss. However, children with CIs still fall short of fulfilling some other needs, including musical perception. This is often attributed to the biological, technological, and acoustic limitations of CIs. Emotions play a key role in the understanding and enjoyment of music. The present study aimed to in...

متن کامل

Study and Comparison of Formant Characteristics of Persian Vowels in 4-7-year-old Children Using Cochlear Implants and Those Using Hearing Aids

Background and Objective: One of the most important physical properties of vowels is their formant structure. One of the most obvious speech errors in hearing-impaired children is vowel errors. The present study aimed to determine and compare the formant structure of Persian vowels in deaf and cochlear implant children in the age range of 4-7 years. Materials and Methods: This descriptive-anal...

متن کامل

Correlation between Auditory Spectral Resolution and Speech Perception in Children with Cochlear Implants

Background: Variability in speech performance is a major concern for children with cochlear implants (CIs). Spectral resolution is an important acoustic component in speech perception. Considerable variability and limitations of spectral resolution in children with CIs may lead to individual differences in speech performance. The aim of this study was to assess the correlation between auditory ...

متن کامل

Comparison of the high-frequency morpho-syntactic structures of cochlear implant children and children with normal hearing aged 4-6 years

Introduction: Children with cochlear implants experience problems at all language domains, and have more problems in morpho-syntactic skills than others domains. Considering the importance of morphology and syntax in developing of communication skills of children, this study compared the use of high-frequency morpho-syntactic structures among 4-6 years old children with cochlear implants and ty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011