Diffraction-limited 800nm imaging with the 2.56m Nordic Optical Telescope

نویسنده

  • J. E. Baldwin
چکیده

A quantitative assessment is presented of diffraction-limited stellar images with Strehl ratios of 0.250.30 obtained by selection of short-exposure CCD images of stars brighter than +6m at 810nm with the Nordic

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lucky Imaging: High Angular Resolution Imaging in the Visible from the Ground

We use a Lucky Imaging system to obtain I-band images with improved angular resolution on a 2.5m telescope. We present results from a 10-night assessment campaign on the 2.56m Nordic Optical Telescope and quantify the performance of our system in seeings better than 1.0”. In good seeing we have acquired near diffraction-limited images; in poorer seeing the angular resolution has been routinely ...

متن کامل

ar X iv : a st ro - p h / 01 09 00 9 v 1 2 S ep 2 00 1 Optical Observations of the Dark Gamma - Ray Burst GRB 000210

We report on optical observations on GRB 000210 obtained with the 2.56m Nordic Optical Telescope and the 1.54-m Danish Telescope starting 12.4 hours after the gamma-ray event. The content of the X-ray error box determined by the Chandra satellite is discussed.

متن کامل

Proposed instrumentation for PILOT

PILOT (the Pathfinder for an International Large Optical Telescope) is a proposed Australian/European optical/infrared telescope for Dome C on the Antarctic Plateau, with target first light in 2012. The proposed telescope is 2.4m diameter, with overall focal ratio f/10, and a 1 degree field-of-view. In median seeing conditions, it delivers 0.3" FWHM widefield image quality, from 0.7-2.5 microns...

متن کامل

Diffraction-limited Imaging with Ground-based Optical Telescopes

The construction of diffraction-limited images with ground-based optical telescopes by means of closure-phase observations is explored. The effect of redundant baselines on closure-phase observations is analyzed, and it is shown that for bright objects a nonredundant-mask approach is superior to the use of the full aperture. Observations of closure phase with a nonredundant mask on the 200 in. ...

متن کامل

Super-resolution optical telescopes with local light diffraction shrinkage

Suffering from giant size of objective lenses and infeasible manipulations of distant targets, telescopes could not seek helps from present super-resolution imaging, such as scanning near-field optical microscopy, perfect lens and stimulated emission depletion microscopy. In this paper, local light diffraction shrinkage associated with optical super-oscillatory phenomenon is proposed for real-t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000