An 8-channel metamaterial T-R coil at 9.4T

نویسندگان

  • A. Senn
  • A. Peter
  • J. G. Korvink
چکیده

Introduction In this contribution, we present a multi-channel T/R coil for use in a 9.4T animal scanner system. Each coil element comprises a composite right/left-handed (CRLH) metamaterial transmission line (MTL). Eight of these elements were arranged in a circular manner to constitute a multi channel coil. MTLs offer the feature of a homogenous current distribution along the line when they are tuned to their 0-order resonance. This leads to a homogenous T/R sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Actively Detunable 8-channel Small Animal Transceive Volume Array for 9.4T MRI systems

Introduction Ultra-high field MRI systems for small animals have seen a rapid development over recent years in a continuous effort to enhance SNR and spectral resolution of MRI images. To circumvent the associated high-field B1 inhomogeneity problem, methods such as RF shimming and Transmit SENSE have been proposed [1-2]. To benefit from the advantages of these techniques, dedicated phased-arra...

متن کامل

A Stripline-like Coil Element Structure for High Field Phased Array Coils and its Application for a 8-channel 9.4T Small Animal Transceive Array

Introduction Ultra-high magnetic field strength, as widely utilised in small animal MRI systems, has advantages of being able to enhance signal-to-noise ratio (SNR) and gain high spectral resolution [1]. However, the homogeneity of B1 field worsens along with the move to higher RF-frequencies. Methods such as RF shimming and transmit SENSE, which require transceive volume-arrays had been propos...

متن کامل

A Novel 8-Channel Transceive Volume-Array for a 9.4T Animal Scanner

Introduction This work focuses on the design of a novel 8-element TX/RX volume-array for high field animal MRI. The magnetic field strength of current small animal MRI systems is increasing in search of higher SNR and spectral resolution [1]. Along with the move to higher field strengths, RF coil design for small-animal MRI is advancing concurrently [2]. At ultra high field strengths, however, ...

متن کامل

Phased Array Imaging in Mouse Hearts using an 8-Channel Phased Array Coil at 9.4 Tesla

Introduction: Cardiac magnetic resonance imaging (CMR) in surgically or genetically modified mice is typically performed using single dedicated volume or surface coils. The development of coil arrays to speed-up CMR becomes more challenging with increasing magnetic field strength and reduced bore size of the magnet. While the use of coil arrays for cardiac MR exams of the human heart is well es...

متن کامل

High resolution anatomical and quantitative MRI of the entire human occipital lobe ex vivo at 9.4 T

Several magnetic resonance imaging (MRI) contrasts are sensitive to myelin content in gray matter in vivo which has ignited ambitions of MRI-based in vivo cortical histology. Ultra-high field (UHF) MRI, at fields of 7T and beyond, is crucial to provide the resolution and contrast needed to sample contrasts over the depth of the cortex and get closer to layer resolved imaging. Ex vivo MRI of hum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010