Penetration of the Descending Colon by a Migrating Intrauterine Contraceptive Device

نویسندگان

  • Jung Min Park
  • Chang Seog Lee
  • Min Seong Kim
  • Do Young Kim
  • Chul Young Kim
  • Young Bae Lim
  • Yong Kyu Lee
  • Dong Eun Park
  • Dong Hyun Lee
چکیده

Foreign bodies in the gastrointestinal tract often cause serious complications, such as perforation, obstruction, abscess formation, or hemorrhage. This is a case in which a patient visited our hospital and complained of a vague lower abdominal pain that had been present for three months. She had an intrauterine device (IUD) inserted five years earlier. The abdominal X-ray, computed tomography and colonoscopy revealed that the IUD had penetrated into the descending colon. We tried to remove the IUD by colonoscopy but failed due to pain, so we removed the IUD surgically. Thus, we report a case in which a previously inserted IUD had penetrated into the descending colon and was surgically removed. We also present a brief review of the literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Migration of an intrauterine contraceptive device into the sigmoid colon.

We present a case of migrating copper-T intrauterine contraceptive device (IUCD) into the bowel wall at the recto-sigmoid junction, and the colonoscopic retrieval of the device. This case introduces the possibility of safe rectal retrieval of migrating IUCD implanted into the bowel wall.

متن کامل

Surgical options for the retrieval of a migrated intrauterine contraceptive device

The intrauterine contraceptive device is a popular form of contraception for women; however, it does carry a rare but serious risk of migration into the myometrium and then into the peritoneal cavity. We report an unusual case of an intrauterine contraceptive device (IUCD) migrating through the uterus into the peritoneal cavity and subsequently into the sigmoid colon, which was finally retrieve...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

An Unusual Case of a Forgotten Intrauterine Contraceptive Device Which was Found Embedded in the Rectosigmoid Colon

An intrauterine contraceptive device (IUD) is an effective, safe and convenient contraceptive method. It can cause serious complications like uterine perforation during the insertion process. The perforation of the bowel by the IUD is usually symptomatic, but asymptomatic colon perforation has rarely been reported. We are reporting one such case of a forgotten IUD, which perforated through the ...

متن کامل

Pelvic abscess complicating sigmoid colon perforation by migrating intrauterine device: A case report and review of the literature

INTRODUCTION Intrauterine devices (IUDs) are commonly used as a contraceptive method. However, they may cause rare but potentially serious complications such as migration through the uterine wall and gastrointestinal perforation. PRESENTATION OF CASE We report a case of a 26-year woman, carrying an IUD for 2 years, who presented to the emergency with pelvic pain with breakthrough bleeding. Ab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2010