Diagnostic applications of simultaneously acquired dual-isotope single-photon emission CT scans.

نویسندگان

  • D Mathews
  • B S Walker
  • B C Allen
  • H Batjer
  • P D Purdy
چکیده

PURPOSE To report the development and validation of a technique of dual tracer single-photon emission CT brain imaging using technetium-99m hexamethylpropyleneamine oxime and iodine-123 iodoamphetamine agents and the application of this technique in patients with a variety of diagnoses. METHODS Contamination between the two isotopes' energy windows was calculated by opening both energy windows while scanning a group of patients using a single isotope. To compare uniformity of I-123 down-scatter, Tc-99m studies were performed both before and after the administration of I-123 in five of 24 dual studies. The 24 patients studied with the dual-isotope technique were evaluated during acetazolamide testing, trial balloon occlusion, or embolization of an arteriovenous malformation. RESULTS In a dual acquisition, average count contamination of an I-123 study by Tc-99m was less than 1% of the total I-123 counts, and contamination of a Tc-99m study by I-123 was approximately 12% of the total Tc-99m counts. Tc-99m studies performed both before and after the administration of I-123 demonstrated that contaminating counts do not adversely affect scan interpretation. Dual-tracer scans were completed in all 24 patients, 10 of whom showed changes after intervention. CONCLUSIONS Dual-tracer single-photon emission CT brain scans of adequate diagnostic quality are possible using Tc-99m and I-123.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous SPECT imaging of multi-targets to assist in identifying hepatic lesions

Molecular imaging technique is an attractive tool to detect liver disease at early stage. This study aims to develop a simultaneous dual-isotope single photon emission computed tomography (SPECT)/CT imaging method to assist diagnosis of hepatic tumor and liver fibrosis. Animal models of liver fibrosis and orthotopic human hepatocellular carcinoma (HCC) were established. The tracers of (131)I-NG...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Evaluation of mandibular invasion by head and neck cancers using 99mTc-methylene diphosphonate or 99mTc-hydroxymethylene diphosphonate and 201Tl chloride dual isotope single photon emission computed tomography.

Whether a patient with head and neck cancer has mandibular invasion or not is important in determining the method of resection surgery. But, no modality is adequately reliable when used alone in the evaluation of mandibular invasion. Therefore, to more accurately diagnose mandibular invasion in head and neck cancer, we used a new modality, namely, 99mTc methylene diphosphonate (MDP) or 99mTc hy...

متن کامل

New Imaging Protocols for New Single Photon Emission CT Technologies

Nuclear cardiology practitioners have several new technologies available with which to perform myocardial perfusion single photon emission CT (MPS). These include dedicated small-footprint cardiac scanners, new stationary or semi-stationary three-dimensional detectors, and advanced software algorithms for optimal image reconstruction. These new technologies have been employed to reduce imaging ...

متن کامل

Validation of mutual information-based registration of CT and bone SPECT images in dual-isotope studies

The registration of computed tomography (CT) and nuclear medicine (NM) images can substantially enhance patient diagnosis as it allows for the fusion of anatomical and functional information, as well as the attenuation correction of NM images. However, irrespective of the method used, registration accuracy depends heavily on the characteristics of the images that are registered and the degree o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 1994