Release of Chromium from Orthopaedic Arthroplasties

نویسندگان

  • G.A. Afolaranmi
  • J Tettey
  • R.M.D Meek
  • M.H Grant
چکیده

Many orthopaedic implants are composed of alloys containing chromium. Of particular relevance is the increasing number of Cobalt Chromium bearing arthroplasies being inserted into young patients with osteoarthritis. Such implants will release chromium ions. These patients will be exposed to the released chromium for over 50 years in some cases. The subsequent chromium ion metabolism and redistribution in fluid and tissue compartments is complex. In addition, the potential biological effects of chromium are also controversial, including DNA and chromosomal damage, reduction in CD8 lymphocyte levels and possible hypersensitivity reactions (ALVAL). The establishment of these issues and the measurement of chromium in biological fluids is the subject of this review.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty

BACKGROUND All prostheses with metallic components release metal debris that can potentially activate the immune system. However, implant-related metal hyper-reactivity has not been well characterized. In this study, we hypothesized that adaptive immunity reaction(s), particularly T-helper type 1 (Th1) responses, will be dominant in any metal-reactivity responses of patients with total joint re...

متن کامل

Failure of total hip implants: metals and metal release in 52 cases.

BACKGROUND The pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. OBJECTIVES To assess cobalt, nickel and chromium(VI) release from, and the metal composition of, failed metal-on-ethylene to...

متن کامل

Chromium oxide coatings with the potential for eliminating the risk of chromium ion release in orthopaedic implants

Chromium oxide coatings prepared by radiofrequency reactive magnetron sputtering on stainless steel substrates were exposed to Ringer's physiological solution and tested for their electrochemical corrosion stability using an open circuit potential measurement, potentiodynamic polarization, electrochemical impedance spectroscopy and Mott-Schottky analysis. The coatings were found to be predomina...

متن کامل

Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis

BACKGROUND Metal-on-metal (MOM) total hip arthroplasties were reintroduced because of the problems with osteolysis and aseptic loosening related to polyethylene wear of early metal-on-polyethylene (MOP) arthroplasties. The volumetric wear rate has been greatly reduced with MOM arthroplasties; however, because of nano-size wear particles, the absolute number has been greatly increased. Thus, a s...

متن کامل

Staged bilateral hip or knee arthroplasties.

PURPOSE To compare the operating time, amount of blood transfused, length of hospital stay, and early complications (within 6 months) between 2-week staged bilateral arthroplasties and matched randomised controls undergoing unilateral arthroplasties. METHODS From October 1992 to October 2000, 90 patients who underwent bilateral hip or knee arthroplasties with a 2-week interval were compared w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Open Orthopaedics Journal

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008