Multipoint laser Doppler vibrometry with single detector: principles, implementations, and signal analyses.

نویسندگان

  • Y Fu
  • M Guo
  • P B Phua
چکیده

A 20-point laser Doppler vibrometer with single photodetector is presented for noncontact dynamic measurement. A 5×4 beam array with various frequency shifts is generated by a 1.55 μm distributed feedback laser and four acousto-optic devices, and illuminating different points on vibrating objects. The reflected beams are coupled into a single-mode fiber by a pigtailed collimator and interfere with a reference beam. The signal output from a high-speed photodetector is amplified and then digitized by a high-speed analog-to-digital converter with a sampling rate of 1 gigasample per second (1 GS/s). Several methods are introduced to avoid the cross talk among different frequencies and extract the vibration information of 20 points from a one-dimensional signal. Two signal processing algorithms based on Fourier transform and windowed Fourier transform are illustrated to extract the vibration signals at different points. The experimental results are compared with that from a commercial single-point laser vibrometer. The results show simultaneous vibration measurement can be realized on multiple points using a single laser source and a single photodetector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multipoint laser Doppler vibrometry using holographic optical elements and a CMOS digital camera.

A laser Doppler vibrometer (LDV) is described in which holographic optical elements are used to provide the interferometer reference and object illumination beams. A complementary metal-oxide semiconductor camera, incorporating a digital signal processor, is used to carry out real-time signal processing of the interferometer output to allow multipoint LDV to be implemented.

متن کامل

Bayesian Spectrum Analysis for Laser Vibrometry Processing

Laser vibration sensing provides a sensitive non-contact means of measuring vibrations of objects. These measurements are used in industrial quality control and wear monitoring as well as the analysis of the vibrational characteristics of objects. In laser vibrometry, the surface motion is monitored by heterodyne laser Doppler velocimetry, and the received heterodyne signal is sampled to produc...

متن کامل

Tissue blood flow measurement by laser Doppler technique

  Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...

متن کامل

A new method for filtering speckle noise in vibration signals measured by Laser Doppler Vibrometry for on-line quality control

Mechanical fault diagnostics for quality control of manufacturing appliances is often based on the analysis of machine vibrations. In the presence of mechanical faults, vibration signals comprise periodic impulses with a characteristic frequency corresponding to a particular defect. Vibrometers based on LDV (Laser Doppler Vibrometry) are an alternative to the traditional use of piezo-electric a...

متن کامل

Using laser Doppler vibrometry to measure capillary surface waves on fluid-fluid interfaces.

Capillary wave phenomena are challenging to study, especially for microfluidics where the wavelengths are short, the frequencies are high, and the frequency distribution is rarely confined to a narrow range, let alone a single frequency. Those that have been studying Faraday capillary waves generated by vertical oscillation have chosen to work at larger scales and at low frequencies as a soluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 50 10  شماره 

صفحات  -

تاریخ انتشار 2011