Gradient echo imaging.

نویسندگان

  • Michael Markl
  • Jochen Leupold
چکیده

Magnetic resonance imaging (MRI) based on gradient echoes is used in a wide variety of imaging techniques and clinical applications. Gradient echo sequences form the basis for an essential group of imaging methods that find widespread use in clinical practice, particularly when fast imaging is important, as for example in cardiac MRI or contrast-enhanced MR angiography. However, the term "gradient echo sequence" is somewhat unspecific, as even images acquired with the most common sequences employing the gradient echo for data acquisition can significantly differ in signal, contrast, artifact behavior, and sensitivity to, eg, flow. This is due to the different use of sequence timing and basic sequence building blocks such as spoiler gradients or specific radiofrequency (RF) pulse phase patterns. In this article the basic principles of gradient echo formation compared to spin echo imaging are reviewed and the properties of gradient echo imaging in its simplest form (TR ≫ T(2)) are described. Further, the most common three variants of fast gradient echo sequences (TR < T(2)), namely, unbalanced gradient echo, RF spoiled gradient echo, and balanced steady state free precession; are discussed. For each gradient echo sequence type, examples of applications exploiting the specific properties of the individual technique are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The added gradient echo pulse sequence technique: application to imaging of fluid in the temporomandibular joint.

PURPOSE To assess the value of an added gradient echo in the same pulse sequence with a T1-weighted spin echo for determining the presence of an abnormal fluid collection in the temporomandibular joint with no additional imaging time. MATERIALS AND METHODS Using a standard T1-weighted sequence used in cine temporomandibular joint imaging, a readout gradient reversal was added and the resultin...

متن کامل

GRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique.

A novel technique of magnetic resonance (MR) imaging, which combines gradient-echo and spin-echo (GRASE) technique, accomplishes T2-weighted multisection imaging in drastically reduced imaging time, currently 24 times faster than spin-echo imaging. The GRASE technique maintains contrast mechanisms, high spatial resolution, and image quality of spin-echo imaging and is compatible with clinical w...

متن کامل

Perfusion MRI of the human brain with dynamic susceptibility contrast: gradient-echo versus spin-echo techniques.

In this study, spin-echo and gradient-echo-based perfusion magnetic resonance imaging (MRI) techniques are systematically compared with respect to their application in the human brain. Six healthy subjects were evaluated with both techniques consecutively and injected twice with a gadolinium-based contrast agent. In accordance with theoretical predictions and with previous animal experiments, t...

متن کامل

Tissue temperature monitoring with multiple gradient-echo imaging sequences.

The inherent sensitivity of multiple gradient-echo sequences to the chemical shift is exploited to rapidly map muscle water frequency shifts caused by ultrasonic heating. The use of multiple echoes is shown to offer several advantages over single gradient-echo approaches previously proposed for temperature measurement. An increase in the effective bandwidth significantly reduces aliasing proble...

متن کامل

Rapid gradient-echo imaging.

Gradient-echo sequences are widely used in magnetic resonance imaging (MRI) for numerous applications ranging from angiography to perfusion to functional MRI. Compared with spin-echo techniques, the very short repetition times of gradient-echo methods enable very rapid 2D and 3D imaging, but also lead to complicated "steady states." Signal and contrast behavior can be described graphically and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 2012