Analysis of variance of microspheres blood flow measurements in rabbits.

نویسندگان

  • H F Duijm
  • A H Rulo
  • M Astin
  • O Mäepea
  • T J van den Berg
  • E L Greve
چکیده

As part of a larger study on the interpretation of angiographically derived hemodynamic parameters, blood flow in several ocular tissues was measured using the radioactively labelled microspheres technique. As an unexpected secondary results, it was found that the microspheres data gave quantitative information on hyperaemic effects in the eye. This is the subject of the present paper. The measurements were made in 13 anaesthetized pigmented rabbits. In each animal, three blood flow measurements were performed at three different ocular perfusion pressures (60-15 mmHg). The perfusion pressures of the experimental eye were varied by changing the intra-ocular pressure. The contra-lateral eye served as a control. Labelled microspheres were used as a non-recirculating blood flow indicator, enabling the estimation of regional blood flows, in this case for the iris, ciliary body, peripheral choroid and peripapillary choroid separately. Using analysis of variance with perfusion pressure as covariate and taking into account the blood flow of the control eye, hyperaemia could be quantified in the experimental eye. Apart from a difference amongst animals, hyperaemia depended on tissue type. The amount of hyperaemia proved to be more pronounced in the anterior part of the eye, iris and ciliary body, and to decrease towards the posterior pole. With regard to the causes of this hyperaemia one could speculate about the invasive handling (anterior eye needles) topical administration of tropicamide, in combination with the general anaesthesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF CARRAGEENAN-INDUCED INFLAMMATION ON BLOOD FLOW IN THE RABBIT KNEE JOINT

Experiments were carried out on anesthetized adult New Zealand rabbits. Acute joint inflammation was achieved by intra-articular injection of 2% carrageenan. Radiolabelled microspheres were used to measure the effect of acute inflammation on blood flow in the knee joint and establish whether neural influences on blood vessel caliber were affected. Surgical exposure of the posterior joint "capsu...

متن کامل

Hemodilution during venous gas embolization improves gas exchange, without altering V(A)/Q or pulmonary blood flow distributions.

BACKGROUND Isovolemic anemia results in improved gas exchange in rabbits with normal lungs but in relatively poorer gas exchange in rabbits with whole-lung atelectasis. In the current study, the authors characterized the effects of hemodilution on gas exchange in a distinct model of diffuse lung injury: venous gas embolization. METHODS Twelve anesthetized rabbits were mechanically ventilated ...

متن کامل

Effect of Angiotensin II on Blood Flow in Acute and Chronically Inflamed Knee Joints of Rabbits: The Role of Nitric Oxide

Background: Angiotensin converting enzyme (ACE) upregulation in stromal cells of joints affected by rheumatoid arthritis may lead to higher tissue angiotensin II that is a vasoconstrictor and mitogen factor. To date, the role of angiotensin II on regulating blood flow in inflamed joints has not been studied. Methods: Acute and chronic joint inflammation was induced in rabbits by intra-articular...

متن کامل

Measurement of regional choroidal blood flow in rabbits and monkeys using fluorescent microspheres.

OBJECTIVE To develop a quantitative measure of regional variation in choroidal blood flow (ChBF). METHODS Five million 15-microm fluorescent microspheres were injected into the left ventricles of 4 rabbits and 3 monkeys. The fixed globes were bleached, flat mounted, and photomicrographed. After image analysis to locate each microsphere, regional densities and blood flow were determined. RES...

متن کامل

On the validity of blood flow measurement using colored microspheres.

The aim of this study was 1) to investigate the validity of repeated estimations of blood flow using colored microspheres (CMS) and 2) to develop and validate a method that permits four consecutive estimations in the same animal using nonradiolabeled microspheres (NRMS). Several mixtures of different types of microspheres were injected in dogs, with each mixture containing the radiolabeled micr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental eye research

دوره 64 4  شماره 

صفحات  -

تاریخ انتشار 1997