Our cumulative experience with transendoscopic miniprobes.

نویسندگان

  • M J Varas
  • R Abad
  • J Turró
  • J C Espinós
چکیده

INTRODUCTION Transendoscopic miniprobes (TEMPs) have nowadays precise indications, but may become a diagnostic alternative to both radial and sectorial endoscopic ultrasonography (EUS) in the near future. PATIENTS AND METHODS From November 1996 to July 2004 we carried out 620 examinations using TEMPs (124 during the last 12 months in 2003, with currently a mean of 11 examinations/month). Twenty explorations were performed with radial, 12.5 MHz (20 mm penetration), 6.2 F (2 mm diameter), 950 mm or 2000 mm Microvasive Endosound probes. Twenty explorations were performed using a 12 MHz (29 mm mean penetration) or 20 MHz (18 mm penetration) Olympus UM-2R/3R, or with a 12 MHz UM-DP12-25R or 20 MHz UM-DP20-25 R DPR-fitted Olympus probe, 2.5 mm in diameter and 2050 mm in length. A 20 MHz, 2.2 mm, wire-guided G20-29R was used for intraductal studies. In all, 580 examinations were carried out with both radial and linear, 12 MHz (240 E) or 20 MHz (60 E) Fuji probes, 2.6 mm in diameter and 1900 mm in length; and with a 7.5 MHz, 2.6 mm radial balloon microprobe with the well-known "preload" system that we have been using during the 1999-2004 period (280 E). Here we used a 3.2 mm working channel, whereas a 2.8 mm working channel was used with the remaining TEMPs. RESULTS Twenty GI-tract examinations were performed with one Microvasive probe, which broke down when attempting its passage through the papilla. Currently we use a 20 MHz, 2.2 mm Olympus G20-29R guided microprobe for intraductal studies. We performed 100 gut examinations using one single Fuji TEMP (12 or 7.5 MHz). Organs explored included: esophagus and stomach, 60%; rectum and colon, 30%; other (duodenum, papilla, bile ducts), 10%. INDICATIONS cancer staging, 35%; submucosal lesions, 30%; other, 35% (including 20% of esophageal non-tumoral conditions). COMPLICATIONS aspiration, perforation, and mortality, 0%. Morbidity, 10%, at the expense of abdominal pain as induced by endoscopy itself. All strictures were successfully passed, except for one malignant stenosis in the rectum. CONCLUSIONS During a 93-month period (1996-2004) we performed 620 explorations with TEMPs, with a current average of 11 examinations/month. TEMP durability is around 100 gut explorations. The esophagus and stomach were examined in 60% of cases. Primary indications included gut cancer staging and submucosal lesions (65%). Perforation and mortality rates amounted to 0%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endosonographic characteristics of submucosal tumors (SMT). Approach and algorithm.

Submucosal lesions (SMLs) of the upper gastrointestinal tract (1-4) represent a significant diagnostic and therapeutic challenge to both endoscopists and gastroenterologists. Such lesions may be assessed by using multifrequency transendoscopic miniprobes, or endoscopic ultrasonography (EUS), either radial or linear. Fine-needle puncture-aspiration (FNA) of SMTs should be guided by only linear EUS.

متن کامل

Colon carcinoma staging by endoscopic ultrasonography miniprobes

BACKGROUND AND OBJECTIVES Due to the increasing use of endoscopic techniques for colon cancer resection, pretreatment locoregional staging may gain critical interest. The use of endoscopic ultrasonography (EUS) miniprobes in this context has been seldom reported. Our aim was to determine the accuracy of EUS miniprobes for colon cancer staging. MATERIALS AND METHODS Forty patients with colon c...

متن کامل

Cooperative hybridization of γPNA miniprobes to a repeating sequence motif and application to telomere analysis.

GammaPNA oligomers having one or two repeats of the sequence AATCCC were designed to hybridize to DNA having one or more repeats of the complementary TTAGGG sequence found in the human telomere. UV melting curves and surface plasmon resonance experiments demonstrate high affinity and cooperativity for hybridization of these miniprobes to DNA having multiple complementary repeats. Fluorescence s...

متن کامل

A Standardized Bronchoalveolar Lavage (BAL) Technique Using Large Volume of Infused Fluid in Young Foals under Intravenous General Anesthesia

The purpose of this paper is to describe a standardized bronchoalveolar lavage (BAL) technique used in 11 clinically healthy foals from one week of age to2 months of age. All foals successfully underwent this procedure five times at different ages. This technique was performed under intravenous general anesthesia with no apparent complications. In our experience, performing transendoscopic BAL ...

متن کامل

Cumulative Live-Birth Rates by Maternal Age after One or Multiple In Vitro Fertilization Cycles: An Institutional Experience

Background: The aim of this retrospective study is to investigate the cumulative live birth rate (CLBR) following one or more completed in vitro fertilization (IVF) cycles (up to 6 cycles) stratified by maternal age and type of infertility. Materials and Methods: In this retrospective study, five hundred forty-seven women who received 736 fresh ovarian stimulation/embryo transfer cycles between...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva

دوره 97 6  شماره 

صفحات  -

تاریخ انتشار 2005