Efficacy of removal of cariogenic bacteria and carious dentin by ablation using different modes of Er:YAG lasers
نویسندگان
چکیده
The primary objective of this in vitro study was to evaluate the efficiency of removal of cariogenic bacteria and carious dentin by ablation using two lasers: fluorescence-feedback controlled (FFC) Er:YAG laser and different pulses of Er:YAG laser based on variable square pulse technology (VSPt). The secondary objective was to measure the temperature during laser ablation of carious tissue. Seventy-two extracted human molars were used in this study. Sixty teeth with carious dentin were randomly divided into four experimental groups according to the treatment for caries removal: group 1: 400 µs (FFC group); group 2: super short pulse (SSP group, 50 µs pulse); group 3: medium short pulse (MSP group, 100 µs pulse); group 4: short pulse (SP group, 300 µs pulse) and one positive control group with no treatment. Twelve teeth without carious lesion were used as a negative control group. After caries removal, swabs were taken with cotton pellets and real-time PCR analysis was performed. During caries ablation, a thermal infrared camera was used to measure the temperature changes. In all experimental groups, specimens were free of bacterial contamination after the treatment. In the SSP, MSP and SP groups, temperatures measured during caries ablation were significantly higher compared to temperatures in the FFC group (P<0.001). In this in vitro study, laser treatment for removal of carious dentin and cariogenic bacteria was an efficient treatment modality without causing excessive temperatures that might adversely affect pulp vitality.
منابع مشابه
Application of DIAGNOdent as a guide for removing carious dentin with Er:YAG laser.
OBJECTIVES The purpose of this study was to investigate the DIAGNOdent values applicable as a guide for removal of outer layer of carious dentin with Er:YAG laser. METHODS Carious dentin of human extracted molars was removed by bur with Caries Detector (Group 1: red stained dentin was left, Group 2: light pink stained dentin was left) and by Er:YAG laser with DIAGNOdent value as a guide (30>G...
متن کاملMicroindentation hardness and calcium/phosphorus ratio of dentin following excavation of dental caries lesions with different techniques
BACKGROUND The aim of this in vitro study was to evaluate the microindentation hardness and chemical composition of residual dentin left at the cavity bottom following removal of carious dentin using the Carisolv chemomechanical and Er:YAG laser caries excavation methods in comparison with the conventional tungsten-carbide bur excavation. METHODS Sixty-nine extracted permanent teeth with occl...
متن کاملComparison of the Efficacy of Chemomechanical Caries Removal (Papacarie - A Papain Gel) and Conventional Excavation in Reducing Cariogenic Flora: An In Vivo Study
Background: Aim of this study was to compare the efficacy of chemomechanical caries removal (CMCR) (Papacarie) with that of conventional excavation in reducing the count of the cariogenic flora checked on blood agar plates. Materials and Methods: A total of 40 molar teeth (n = 40) were divided into two groups of 20 teeth each. In the first group, caries was removed using Papacarie gel and in se...
متن کاملComparison of Er:yag and Er:ysgg Laser Ablation of Dental Hard Tissues
To compare ablation quality of Er:YAG and Er:YSGG laser the surface quality, crater shape, mass loss, and temperature development were determined using the same fibre transmission system and handpiece. Similar crater depths for both lasers but greater diameters for the Er:YAG laser were measured. Also mass loss per pulse of the Er:YAG laser exceeds that of the Er:YSGG laser. Temperature develop...
متن کاملComparison of Heat Deposition of Er:YAG and Er,Cr:YSGG Lasers in Hard Dental Tissues
This paper describes a comparative study of residual heat deposition of Er:YAG and Er,Cr:YSGG lasers during ablation of hard dental tissues. Residual heat deposition was obtained from measured irradiated hard tissue temperature decay characteristics immediately following Erbium laser pulses. The measured residual heat was larger in enamel than in dentine for both Er:YAG and Er,Cr:YSGG sources. ...
متن کامل