Estimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture
نویسندگان
چکیده
Ground reaction forces and moments (GRF&M) are important measures used as input in biomechanical analysis to estimate joint kinetics, which often are used to infer information for many musculoskeletal diseases. Their assessment is conventionally achieved using laboratory-based equipment that cannot be applied in daily life monitoring. In this study, we propose a method to predict GRF&M during walking, using exclusively kinematic information from fully-ambulatory inertial motion capture (IMC). From the equations of motion, we derive the total external forces and moments. Then, we solve the indeterminacy problem during double stance using a distribution algorithm based on a smooth transition assumption. The agreement between the IMC-predicted and reference GRF&M was categorized over normal walking speed as excellent for the vertical (ρ = 0.992, rRMSE = 5.3%), anterior (ρ = 0.965, rRMSE = 9.4%) and sagittal (ρ = 0.933, rRMSE = 12.4%) GRF&M components and as strong for the lateral (ρ = 0.862, rRMSE = 13.1%), frontal (ρ = 0.710, rRMSE = 29.6%), and transverse GRF&M (ρ = 0.826, rRMSE = 18.2%). Sensitivity analysis was performed on the effect of the cut-off frequency used in the filtering of the input kinematics, as well as the threshold velocities for the gait event detection algorithm. This study was the first to use only inertial motion capture to estimate 3D GRF&M during gait, providing comparable accuracy with optical motion capture prediction. This approach enables applications that require estimation of the kinetics during walking outside the gait laboratory.
منابع مشابه
Estimating the Complete Ground Reaction Forces and Moments during Walking Using Inertial Motion Capture
Whole-body inverse dynamics techniques have been recently proposed to assess the ground reaction forces and moments (GRF&M) only from motion data. Even though such techniques remove the dependency on force plate measurements, they are still bounded by the restrictions imposed by optical motion capture, i.e. the limited marker tracking volume, increased complexity, and requirement of a laborator...
متن کاملEstimation of Vertical Ground Reaction Forces and Sagittal Knee Kinematics During Running Using Three Inertial Sensors
Analysis of running mechanics has traditionally been limited to a gait laboratory using either force plates or an instrumented treadmill in combination with a full-body optical motion capture system. With the introduction of inertial motion capture systems, it becomes possible to measure kinematics in any environment. However, kinetic information could not be provided with such technology. Furt...
متن کاملThree-dimensional joint reaction forces and moments at the low back during over-ground walking in persons with unilateral lower-extremity amputation.
BACKGROUND Abnormal mechanics of locomotion following lower-extremity amputation are associated with increases in trunk motion, which in turn may alter loads at the low back due to changes in inertial and gravitational demands on the spine and surrounding trunk musculature. METHODS Over-ground gait data were retrospectively compiled from two groups walking at similar self-selected speeds (~1....
متن کاملA Low Friction Demanding Approach in Gait Planning for Humanoid Robots During 3D Manoeuvres
This paper proposes a gait planning approach to reduce the required friction for a biped robot walking on various surfaces. To this end, a humanoid robot with 18 DOF is considered to develop a dynamics model for studying various 3D manoeuvres. Then, feasible trajectories are developed to alleviate the fluctuations on the upper body to resemble human-like walking. In order to generate feasible w...
متن کاملMethodological factors affecting joint moments estimation in clinical gait analysis: a systematic review
Quantitative gait analysis can provide a description of joint kinematics and dynamics, and it is recognized as a clinically useful tool for functional assessment, diagnosis and intervention planning. Clinically interpretable parameters are estimated from quantitative measures (i.e. ground reaction forces, skin marker trajectories, etc.) through biomechanical modelling. In particular, the estima...
متن کامل