BACKGROUND Coronary occlusion techniques during OPCAB may lead to an endothelial damage to the target vessel. The adverse effects of these techniques are well-known, and researches have been trying to find out new materials to occlude the coronary artery without an endothelial damage. In the present study, we investigate to the endothelial damage in the rat aorta which is occluded by Poloxamer 407 gel. METHODS Forty-five rats were randomized in three groups: (1) segment of the aorta was occluded with Poloxamer 407 gel in P 407 group; (2) segment of the aorta was occluded with microvascular clamp in MV clamp group; and (3) no onclusion was available in the Control group. The rats were sacrificed of observation, and a 15mm segment of the aorta was obtained as a specimen. Integrity of the endothelial lining was observed with a scanning electron microscopy. RESULTS Scanning electron microscopy revealed a statistically significant difference among the 3 groups (p<0,001) using the SPSS 13.0 test. No difference was found between the Control group and the P 407 group (p=0,059). The differences between MV clamp-Control group (p<0,001) and MV clamp-P 407 group were statistically significant (p<0,002). CONCLUSIONS We suggest that Poloxamer 407 gel occlusion may be a safer and more effective method compared to the microvascular clamp occlusion.
منابع مشابه
Correction: Effects of temporary vascular occluder poloxamer 407 Gel on the endothelium
After publication of the article by Gücü et al. [1], it was found that Dr Onder Bozkurt had been inadvertently omitted from the author list. The author list has therefore been amended accordingly. The authors apologise for any inconvenience this may cause. which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Com...
متن کاملThermogelling properties of purified poloxamer 407
Poloxamers are triblock copolymers with a center block of hydrophobic polypropylene oxide (PPO) flanked by two hydrophilic polyethyleneoxide (PEO) blocks. Among this family of copolymers, poloxamer 407 is a non-ionic surfactant with reversible gelation properties above a particular polymer concentration and a particular temperature. Easy preparation of poloxamer 407 based sterile injectable for...
متن کاملEvaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model
Despite progress in the design of advanced surgical techniques, stenosis recurs in a large percentage of vascular anastomosis. In this study, a novel heparin-poloxamer (HP) hydrogel was designed and its effects for improving the quality and safety of vascular anastomosis were studied. HP copolymer was synthesized and its structure was confirmed by Fourier transform infrared spectroscopy (FTIR) ...
متن کاملMethylated arginine analogues: their potential role in atherosclerosis and cognition using the poloxamer-407-induced mouse model of dyslipidemia.
An experimental mouse model of dyslipidemia and atherosclerosis was utilized to study the generation of methylarginines in vivo, as well as any potential behavioral changes in mice associated with the production of excess methylarginines. Following 14 weeks of poloxamer 407 treatment, mice developed atherosclerosis and the plasma concentrations of monomethylarginine and asymmetric dimethylargin...
متن کاملEndothelial function and myogenic reactivity in small mesenteric arteries of hyperlipidemic pregnant rats.
Supraphysiological increases in serum triglycerides and cholesterol often occur during pregnancy, but their effects on vascular function are poorly understood. Intraperitoneal injection of the nontoxic surfactant poloxamer 407 (P-407) results in sustained elevation of triglycerides and cholesterol. We asked if P-407-induced hyperlipidemia during late pregnancy adversely affects mesenteric resis...
متن کامل