Fluid-Structure Interaction Models of Bicuspid Aortic Valves: The Effects of Nonfused Cusp Angles.

نویسندگان

  • Karin Lavon
  • Rotem Halevi
  • Gil Marom
  • Sagit Ben Zekry
  • Ashraf Hamdan
  • Hans Joachim Schäfers
  • Ehud Raanani
  • Rami Haj-Ali
چکیده

Bicuspid aortic valve (BAV) is the most common type of congenital heart disease, occurring in 0.5-2% of the population, where the valve has only two rather than the three normal cusps. Valvular pathologies, such as aortic regurgitation and aortic stenosis, are associated with BAVs, thereby increasing the need for a better understanding of BAV kinematics and geometrical characteristics. The aim of this study is to investigate the influence of the nonfused cusp (NFC) angle in BAV type-1 configuration on the valve's structural and hemodynamic performance. Toward that goal, a parametric fluid-structure interaction (FSI) modeling approach of BAVs is presented. Four FSI models were generated with varying NFC angles between 120 deg and 180 deg. The FSI simulations were based on fully coupled structural and fluid dynamic solvers and corresponded to physiologic values, including the anisotropic hyper-elastic behavior of the tissue. The simulated angles led to different mechanical behavior, such as eccentric jet flow direction with a wider opening shape that was found for the smaller NFC angles, while a narrower opening orifice followed by increased jet flow velocity was observed for the larger NFC angles. Smaller NFC angles led to higher concentrated flow shear stress (FSS) on the NFC during peak systole, while higher maximal principal stresses were found in the raphe region during diastole. The proposed biomechanical models could explain the early failure of BAVs with decreased NFC angles, and suggests that a larger NFC angle is preferable in suture annuloplasty BAV repair surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cusp height in aortic valves.

OBJECTIVES Successful aortic valve repair must normalize cusp and root dimensions. Limited information is available on the normal dimensions of human cusps, in particular the cusp height. METHODS The cusp height was measured intraoperatively in 621 patients during aortic valve repair procedures. A tricuspid anatomy was present in 329 patients and bicuspid in 286 patients. In addition, patient...

متن کامل

Valsalva sinus asymmetry in bicuspid aortic valve: diameter through fused cusp is smaller than diameter through nonfused cusp but maximal diameter is the same whatever the phenotype when estimated by CMR

Background Previous studies establish a link between bicuspid aortic valve (BAV) morphology and aortic shape. Anteroposterior (AP) leaflets with right left (RL) fusion was found more often associated with dilatation of VS than left-right (LR) leaflets with either fusion between right and noncoronary(R-NC) cusps or between left and noncoronary cusps(L-NC). However, most of these studies were per...

متن کامل

Bicuspid aortic valve. Comparison of congenital and acquired types.

Two dominant types of congenital bicuspid valves are described. The classical type is characterized by the presence of a low ridge or raphe along the aortic aspect of the conjoined cusp. The other is characterized by a tall raphe, the upper edge of which corresponds with the upper level of the aortic cusps. Some such ridges may result from acquired fusion of the adjacent halves of two cusps (yi...

متن کامل

Mucoid dysplasia of tricuspid and congenital bicuspid aortic valves in Syrian hamsters (Mesocricetus auratus).

A histological study was made of the aortic valves of 141 Syrian hamsters aged between 35 and 657 days, belonging to an inbred laboratory colony with a high incidence of congenital bicuspid aortic valves. A tricuspid aortic valve was found in 81 specimens, whereas the remaining 60 possessed a bicuspid aortic valve. In all bicuspid valves there were two aortic sinuses, a ventral and a dorsal, ea...

متن کامل

Combined abnormalities of semilunar valves: quadricuspid pulmonary and bicuspid aortic valves.

A42-year-old man was referred to our hospital for evaluation of systolic and diastolic murmurs at the left sternal border. Transthoracic 2D echocardiography revealed a quadricuspid pulmonary valve (Figure 1A) and a bicuspid aortic valve (Figure 1B). Transvalvular flow velocities at the pulmonary and aortic valves were 1.8 m/s and 1.7 m/s, respectively, suggesting mild pulmonary stenosis. Additi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 140 3  شماره 

صفحات  -

تاریخ انتشار 2018