The self-locking Balgrist hip socket for cementless fixation: biomechanical principles and clinical results.

نویسندگان

  • A Schreiber
  • H A Jacob
  • R Hauser
  • S Kern
چکیده

The Balgrist hip socket, initially made entirely of HDPE (high molecular weight polyethylene), now made of outer titanium alloy shell that faces the bone of the acetabulum has been in clinical use for 10 years. The purpose of this presentation is to illustrate the biomechanical principles that have governed this unique design and to present the clinical results that we have obtained until the end of 1991 with 717 implants. From 1982 to 1987 Balgrist HDPE sockets had been implanted for 346 hips, from 1984 to 1991 Balgrist Titanium alloy sockets have been implanted for 371 hips. The number of revision are 55 of 717 hips. 48 hips out of 55 were with Balgrist HDPE sockets. On the contrary, only 7 hips were with Balgrist titanium socket. The greatest benefit of Balgrist Titanium socket is the excellent mechanical lock with subchondral bone of the acetabulum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A cementless, elastic press-fit socket with and without screws

BACKGROUND The acetabular component has remained the weakest link in hip arthroplasty regarding achievement of long-term survival. Primary fixation is a prerequisite for long-term performance. For this reason, we investigated the stability of a unique cementless titanium-coated elastic monoblock socket and the influence of supplementary screw fixation. PATIENT AND METHODS During 2006-2008, we...

متن کامل

The dynamic locking blade plate, a new implant for intracapsular hip fractures: biomechanical comparison with the sliding hip screw and Twin Hook.

Internal fixation of intracapsular hip fractures results in a high failure rate with non-union and avascular necrosis being the two most important complications. In order to prevent these possible complications treatment should consist of an anatomical reduction and stable fixation by insertion of a low volume, dynamic implant, providing angular and rotational stability to the femoral head. Acc...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Use of Wagner cementless self-locking stems for massive bone loss in hip arthroplasty.

OBJECTIVE To assess the use of Wagner cementless self-locking stems for massive bone loss in hip arthroplasty. METHODS 22 patients with severe proximal femoral bone loss either due to prosthetic loosening or comminuted fracture were treated by Wagner cementless self-locking revision stems between November 1993 and June 1995. RESULTS Radiographic evidence of early bony incorporation was foun...

متن کامل

Implant Design in Cementless Hip Arthroplasty

When performing cementless hip arthroplasty, it is critical to achieve firm primary mechanical stability followed by biological fixation. In order to achieve this, it is essential to fully understand characteristics of implant design. In this review, the authors review fixation principles for a variety of implants used for cementless hip replacement and considerations for making an optimal sele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Keio journal of medicine

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 1993