Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs

نویسندگان

  • Gaëtan Guérin
  • Xavier Bourges
  • Frédéric Turquier
چکیده

PURPOSE Tacks and sutures ensure a strong fixation of meshes, but they can be associated with pain and discomfort. Less invasive methods are now available. Three fixation modalities were compared: the ProGrip™ laparoscopic self-fixating mesh; the fibrin glue Tisseel™ with Bard™ Soft Mesh; and the SorbaFix™ absorbable fixation system with Bard™ Soft Mesh. MATERIALS AND METHODS Meshes (6 cm ×6 cm) were implanted in the preperitoneal space of swine. Samples were explanted 24 hours after surgery. Centered defects were created, and samples (either ten or eleven per fixation type) were loaded in a pressure chamber. For each sample, the pressure, the mesh displacement through the defect, and the measurements of the contact area were recorded. RESULTS At all pressures tested, the ProGrip™ laparoscopic self-fixating mesh both exhibited a significantly lower displacement through the defect and retained a significantly higher percentage of its initial contact area than either the Bard™ Soft Mesh with Tisseel™ system or the Bard™ Soft Mesh with SorbaFix™ absorbable fixation system. Dislocations occurred with the Bard™ Soft Mesh with Tisseel™ system and with the Bard™ Soft Mesh with SorbaFix™ absorbable fixation system at physiological pressure (,225 mmHg). No dislocation was recorded for the ProGrip™ laparoscopic self-fixating mesh. CONCLUSION At 24 hours after implantation, the mechanical fixation of the ProGrip™ laparoscopic self-fixating mesh was found to be significantly better than the fixation of the Tisseel™ system or the SorbaFix™ absorbable fixation system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel retrograde puncture method to establish preperitoneal space for laparoscopic direct inguinal hernia repair with internal ring suturing

The aim of this study was to explore the clinical efficacy of a novel retrograde puncture approach to establish a preperitoneal space for laparoscopic direct inguinal hernia repair with inguinal ring suturing. Forty-two patients who underwent laparoscopic inguinal hernia repair with retrograde puncture for preperitoneal space establishment as well as inguinal ring suturing between August 2013 a...

متن کامل

Study protocol for a randomized controlled trial for anterior inguinal hernia repair: transrectus sheath preperitoneal mesh repair compared to transinguinal preperitoneal procedure

BACKGROUND Anterior open treatment of the inguinal hernia with a tension-free mesh has reduced the incidence of hernia recurrence. The Lichtenstein procedure is the current reference technique for inguinal hernia treatment. Chronic pain has become the main postoperative complication after surgical inguinal hernia repair, especially following Lichtenstein. Preliminary experiences with a soft mes...

متن کامل

The clinical effectiveness and cost-effectiveness of open mesh repairs in adults presenting with a clinically diagnosed primary unilateral inguinal hernia who are operated in an elective setting: systematic review and economic evaluation.

BACKGROUNDS Current open mesh techniques for inguinal hernia repair have shown similar recurrence rates. However, chronic pain has been associated with Lichtenstein mesh repair, the most common surgical procedure for inguinal hernia in the UK. The position of the mesh is probably an important factor. The Lichtenstein method requires dissection of the inguinal wall and fixation of the mesh. In c...

متن کامل

Anterior transversalis fascia approach versus preperitoneal space approach for inguinal hernia repair in residents in northern China: study protocol for a prospective, multicentre, randomised, controlled trial

INTRODUCTION Many surgical techniques have been used to repair abdominal wall defects in the inguinal region based on the anatomic characteristics of this region and can be categorised as 'tension' repair or 'tension-free' repair. Tension-free repair is the preferred technique for inguinal hernia repair. Tension-free repair of inguinal hernia can be performed through either the anterior transve...

متن کامل

Use of human fibrin glue (Tisseel) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty (TISTA): a randomized controlled trial (NCT01641718)

BACKGROUND Inguinal hernia repair is one of the most common surgical procedures worldwide. This procedure is increasingly performed with endoscopic techniques (laparoscopy). Many surgeons prefer to cover the hernia gap with a mesh to prevent recurrence. The mesh must be fixed tightly, but without tension. During laparoscopic surgery, the mesh is generally fixed with staples or tissue glue. Howe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014