Mid-term Clinical Results of CO2 Laser-assisted Sclerectomy Surgery (CLASS) for Open-Angle Glaucoma Treatment.

نویسندگان

  • Noa Geffen
  • Michael Mimouni
  • Mark Sherwood
  • Ehud I Assia
چکیده

PURPOSE To evaluate the efficacy and safety of CO2 Laser-assisted Sclerectomy Surgery (CLASS) in primary and pseudoexfoliative open-angle glaucoma. MATERIALS AND METHODS Single-arm, open-label study included data from 9 medical centers located in 7 countries. Subjects underwent nonpenetrating CLASS procedure with a CO2 laser system (IOPtiMate). Intraocular pressure (IOP) and number of medications were measured at baseline, 1, 2, 4, and 6 weeks, and 3, 6, 12, 24, and 36 months. Complete success was defined as 5≤IOP≤18 mm Hg and at least 20% IOP reduction with no medications, and qualified success as the same with or without medications at 12, 24, and 36 months. RESULTS A total of 111 consecutive eyes were enrolled in the study, 14 were excluded from the study due to protocol deviation or operator error. The mean age was 69.3±12.8 and 73.9% were whites. Percent change in IOP from baseline at 1, 2, and 3 years was, respectively, 45.1%, 46.8%, and 42.5% (P<0.001). Complete success rates after 12, 24, and 36 months were 60.2%, 57.9%, and 47.8%, respectively. Qualified success rates after 12, 24, and 36 months were 79.6%, 91.2%, and 84.8%, respectively. Number of medications dropped from 2.39±1.24 to 0.47±0.84, 0.53±0.75, and 0.71±0.89 at 12, 24, and 36 months, respectively (P<0.001). CONCLUSIONS The CLASS procedure may be a simple and effective treatment for open-angle glaucoma providing extended relief of elevated IOP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CO2 laser-assisted sclerectomy surgery, part II: multicenter clinical preliminary study.

PURPOSE To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) in primary and pseudoexfoliative open-angle glaucoma. MATERIALS AND METHODS Patients for primary filtration surgery underwent CLASS with a CO2 laser system (OT-134-IOPtiMate, IOPtima Ltd., Ramat Gan, Israel). This self-controlled system gradually ablates and removes scleral layers until percolating fluid absorb...

متن کامل

Preliminary results of CO2 laser-assisted sclerectomy surgery (CLASS) in the treatment of advanced glaucoma in a Chinese population: Erratum

To evaluate the efficacy and safety of CO2 laser-assisted sclerectomy surgery (CLASS) in Chinese patients with advanced glaucoma.Patients with advanced glaucoma who were candidates for glaucoma filtration surgery were included. The intraocular pressure (IOP) and number of antiglaucoma medications were documented before surgery and at all postoperative clinic visits. All intra- and postoperative...

متن کامل

CO2 laser-assisted deep sclerectomy in glaucoma patients.

PURPOSE To evaluate the safety and efficacy of CO2 laser-assisted deep sclerectomy surgery (CLASS) in patients with open angle glaucoma. DESIGN A prospective single-arm, nonrandomized clinical investigation for the evaluation of technology. METHODS Fifteen eyes of 15 consecutive patients diagnosed with either primary open angle glaucoma or pseudoexfoliation glaucoma who were the candidates ...

متن کامل

Results of CO2 Laser-assisted Deep Sclerectomy as Compared With Conventional Deep Sclerectomy.

PURPOSE To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) compared with classic nonpenetrating deep sclerectomy (NPDS) with implant in medically uncontrolled glaucoma patients. MATERIALS AND METHODS Patients who underwent primary filtration surgery with CO2 laser system at the time interval between July 2010 and April 2011 were identified, their medical files were rev...

متن کامل

CO2 laser-assisted sclerectomy surgery part I: concept and experimental models.

PURPOSE To evaluate the safety and performance of a second-generation device for CO2 laser-assisted sclerectomy surgery system in experimental models. MATERIALS AND METHODS Laser-assisted deep sclerectomy using a modified CO2 laser system (OT-134-"IOPtiMate"; IOPtima Ltd, Israel) was performed in 3 experimental models: enucleated pig eyes, human cadaver eyes, and live rabbit eyes. A half-thic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of glaucoma

دوره 25 12  شماره 

صفحات  -

تاریخ انتشار 2016