BACKGROUND Improper acetabular component orientation in THA has been associated with increased dislocation rates, component impingement, bearing surface wear, and a greater likelihood of revision. Therefore, any reasonable steps to improve acetabular component orientation should be considered and explored. QUESTIONS/PURPOSES We therefore sought to compare THA with a robotic-assisted posterior approach with manual alignment techniques through a posterior approach, using a matched-pair controlled study design, to assess whether the use of the robot made it more likely for the acetabular cup to be positioned in the safe zones described by Lewinnek et al. and Callanan et al. METHODS Between September 2008 and September 2012, 160 THAs were performed by the senior surgeon. Sixty-two patients (38.8%) underwent THA using a conventional posterior approach, 69 (43.1%) underwent robotic-assisted THA using the posterior approach, and 29 (18.1%) underwent radiographic-guided anterior-approach THAs. From September 2008 to June 2011, all patients were offered anterior or posterior approaches regardless of BMI and anatomy. Since introduction of the robot in June 2011, all THAs were performed using the robotic technique through the posterior approach, unless a patient specifically requested otherwise. The radiographic cup positioning of the robotic-assisted THAs was compared with a matched-pair control group of conventional THAs performed by the same surgeon through the same posterior approach. The safe zone (inclination, 30°-50°; anteversion, 5°-25°) described by Lewinnek et al. and the modified safe zone (inclination, 30°-45°; anteversion, 5°-25°) of Callanan et al. were used for cup placement assessment. Matching criteria were gender, age ± 5 years, and (BMI) ± 7 units. After exclusions, a total of 50 THAs were included in each group. Strong interobserver and intraobserver correlations were found for all radiographic measurements (r > 0.82; p < 0.001). RESULTS One hundred percent (50/50) of the robotic-assisted THAs were within the safe zone described by Lewinnek et al. compared with 80% (40/50) of the conventional THAs (p = 0.001). Ninety-two percent (46/50) of robotic-assisted THAs were within the modified safe zone described by Callanan et al. compared with 62% (31/50) of conventional THAs p (p = 0.001). The odds ratios for an implanted cup out of the safe zones of Lewinnek et al. and Callanan et al. were zero and 0.142, respectively (95% CI, 0.044, 0.457). CONCLUSIONS Use of the robot allowed for improvement in placement of the cup in both safe zones, an important parameter that plays a significant role in long-term success of THA. However, whether the radiographic improvements we observed will translate into clinical benefits for patients-such as reductions in component impingement, acetabular wear, and prosthetic dislocations, or in terms of improved longevity-remains unproven.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study.

Obese populations present challenges for acetabular cup placement during total hip arthroplasty (THA). This study examines the accuracy of acetabular cup inclination and version in the obese patient with robotic-assisted computer navigation. A total of 105 patients underwent robotic-assisted computer navigation THA with a posterior approach. Groups were divided on body mass index (BMI, kg/m(2))...

متن کامل

Accuracy of Component Positioning in 2330 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance

Lewinnek et al described a safe zone of acetabular component placement in Total Hip Arthroplasty (THA) to reduce complications. This safe zone is between 10-30 degrees of version and 30-50 degrees of inclination 1 . Callanan et al. reports only 53% of acetabular cups were within Lewinnek’s Safe Zone of optimal cup placement (62% within the abduction safe zone, 79% within the version safe zone)....

متن کامل

Accuracy of Image-based Computer Assisted Surgery in Acetabular Cup Placement for Supine Two-incision Total Hip Arthroplasty

Introduction: Supine patient positioning in conjunction with twoincision minimally invasive surgery (MIS-2 incision) total hip arthroplasty (THA) increases difficulty of accurate and repeatable cup orientation in accordance with pre-operative planning. Investigators have suggested advantages of utilizing computer assisted orthopaedic surgery (CAOS) to successfully eliminate extreme outlying ace...

متن کامل

Predictive value of robotic-assisted total hip arthroplasty.

Acetabular cup positioning, leg-length discrepancy, and global offset are important parameters associated with outcomes following total hip arthroplasty (THA). Deviation from an accepted range of values can lead to significant complications, including dislocation, leg-length discrepancy, impingement, accelerated bearing surface wear, and revisions. The purpose of this study was to assess whethe...

متن کامل

A Comparison of the Conventional (manual) and a Computer-assisted Navigation Method in Total Hip Arthroplasty (tha)

prosthesis model based on CT scans; A detailed acetabular cup is shown at bottom right; A coordinate system and anatomical frontal pelvic plane on the 3D model are shown at bottom left. ASISs are marked black, PTs are in green, and the points on the cup rim are in red. A COMPARISON OF THE CONVENTIONAL (MANUAL) AND A COMPUTER-ASSISTED NAVIGATION METHOD IN TOTAL HIP ARTHROPLASTY (THA) Wixson, R.L...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 472 1  شماره 

صفحات  -

تاریخ انتشار 2014