Implications of an R-Scan for Charm Physics
نویسنده
چکیده
The impact of improved measurements of the cross section for electron-positron annihilation into hadrons in the charm threshold region is discussed. Two aspects are studied in detail: i.) A significant reduction of the experimental error of the electronic width of the narrow resonances J/ψ and ψ and of the continuum cross section from the open charm threshold up to 4.6 GeV will lead to a correspondingly improved determination of the charmed quark mass. ii) A high luminosity measurement with 24 pb−1 at three points and with a spacing of 2 MeV around √ s = 3511MeV may allow to observe the direct, resonant production of χc1.
منابع مشابه
Charm physics: theoretical review
Charm physics plays a unique dual role in the modern investigations of flavor physics. Charm decay and production experiments provide valuable checks and supporting measurements for studies of CP-violation in measurements of CKM parameters in b-physics, as well as outstanding opportunities for searches for new physics. Historically, many methods of heavy quark physics have been first tested in ...
متن کاملHadronic Charm Decays in Cleo
We present several results on hadronic D meson decays. We report on results from the scan of the energy region from 3970 MeV to 4260 MeV, which was used to determine an optimal energy to carry out the Ds physics program of CLEO-c. Improved measurements of inclusive and exclusive D and Ds branching fractions are presented. We also show results on Dalitz analyses of D+ → π+π−π+ using CLEO-c data ...
متن کاملUniversal Approximation of Interval-valued Fuzzy Systems Based on Interval-valued Implications
It is firstly proved that the multi-input-single-output (MISO) fuzzy systems based on interval-valued $R$- and $S$-implications can approximate any continuous function defined on a compact set to arbitrary accuracy. A formula to compute the lower upper bounds on the number of interval-valued fuzzy sets needed to achieve a pre-specified approximation accuracy for an arbitrary multivariate con...
متن کاملDesign and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملComparison of entrance skin dose in the hip region in the imaging of the lower extremity by CT scan and EOS
Introduction: Increasing in refer to computed tomography (CT-scan) imaging causes to increase in cumulative dose. Stereoradiography (EOS) is an X-ray imaging technology that, by eliminating scattering radiation, reduces patient's absorption dose and improves image quality. Materials and Methods: This cross-sectional study was carried out in a hosp...
متن کامل