Tough, but not impossible – Retrieval of large atrial septal occluder devices embolized to left atrium
نویسندگان
چکیده
Atrial septal defect (ASD) is a congenital heart defect that is being increasingly treated using percutaneous interventions. However, these techniques are not devoid of complications. One such complication is device embolization. Removal of such closure device poses tremendous risk and consequent complications both by percutaneous retrieval and surgical removal. Herein, we present two cases of ASDs that were closed using atrial septal occluder, but the devices were subsequently embolized into left atrium. These devices were then percutaneously retrieved without any further complication or injury.
منابع مشابه
Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series
Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...
متن کاملUrgent surgical management for embolized occluder devices in childhood: single center experience
BACKGROUND In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group. METHODS We retrospectively reviewed 9 patients (aged 2-15 years) who underwent urgent surgery due to...
متن کاملPercutaneous Retrieval of Embolized Amplatzer Septal Occluder after Treatment of Double Atrial Septal Defect: A Case Report
Embolization of the occlusion device after percutaneous closure of atrial septal defect (ASD) is a potential disastrous complication. The usual site of embolization is the right side of the heart including pulmonary artery, but the device embolization to the extracardiac aorta is extremely rare. Here, we report a successful percutaneous retrieval case of the embolized Amplatzer Septal Occluder ...
متن کاملSuccessful Percutaneous Retrieval of Embolized Septal Occluder Device from Aortic Arch and Placement of a Newer Septal Occluder Device in Combined Procedure
Embolization of the Amplatzer Septal Occluder (ASO) device (St. Jude Medical, Minnesota) after percutaneous closure of atrial septal defect (ASD) is a rare and potentially catastrophic complication. Percutaneous retrieval of the embolized device is gaining ground as an acceptable method, although these patients are usually subsequently referred for open surgical closure of the ASD. We present a...
متن کاملPercutaneous retrieval of an interatrial septal occluder device embolized into the aortic arch.
Percutaneous closure of secundum atrial septal defects (ASD) may be complicated by immediate embolization. We report on a 35-year-old woman who underwent percutaneous device closure for a secundum ASD. The diameter of the defect was measured as 4 mm by two-dimensional transesophageal echocardiography and a 7-mm Figulla ASD occluder device was implanted without prior balloon sizing of the defect...
متن کامل