Full-field breast tomosynthesis.

نویسنده

  • Andrew Smith
چکیده

Breast tomosynthesis is a 3-dimensional (3-D) imaging technology that involves acquiring images of a stationary compressed breast at multiple angles during a short scan. The individual images are then reconstructed into a series of thin high-resolution slices that displayed individually or in a dynamic ciné mode. Tomosynthesis can reduce or eliminate the tissue overlap effect. While holding the breast stationary, images are acquired at a nsumber of different x-ray source angles. Objects at different heights in the breast project differently for each angle. The final step in the tomosynthesis procedure is reconstructing the data to generate images that enhance objects from a given height by appropriate shifting of the projections relative to one another. There are 3 specific areas in tomosynthesis system requirements that warrant a closer review: detector efficiency and dose, field of view, and equipment geometry. The breast is compressed in a standard way. While holding the breast stationary, the x-ray tube is rotated over a limited angular range. A series of low dose exposures are made every few degrees, creating a series of digital images. Typically, the tuben is rotated about +/-15 degrees, and 11 exposures are made every 3 degrees during a total scan of a few seconds. The individual images are projections through the breast at different angles and these arewhat are reconstructed into slices. There are 2 basic tomosynthesis system designs that diiffer in the motion of the detector during acquisition. One method moves the detector in concert with the x-ray tube so as to maintain the shadow of the breast on the detector. An altemate method is to keep the detector stationary relative to the breast platform. The tomosynthesis reconstruction process consists of computing high-resolution images whose planes are parallel to the breast support plates. Typically, these images are reconstructed with slice separation of 1 mm; thus, a 5 cm compressed breast tomosynthesis study will have 50 reconstructed slices. The reconstructed tomosynthesis slices can be displayed similarly to computed tomography (CT) reconstructed slices. Tomosynthesis could resolve many of the tissue overlap reading problems that are a major source of the need for recalls and additional imaging in 2-D mammography exams.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Review of Digital Breast Tomosynthesis

While the principle of tomosynthesis has been known for almost a century, digital breast tomosynthesis (DBT) is a novel technology that owes its rapid development to the introduction of full-field digital mammography (FFDM). This review article covers the principles and design considerations of DBT, including system geometry. Further, the article provides an in-depth introduction to DBT dosimet...

متن کامل

Screening-detected desmoid tumor of the breast: findings at conventional imaging and digital breast tomosynthesis

Desmoid tumor of the breast is a rare benign entity that usually is mistaken for carcinoma clinically and radiologically. We report two cases of desmoid tumor of the breast detected by mammography screening using digital breast tomosynthesis (DBT). The larger tumor was detected at both full-field digital mammography (FFDM) and DBT. The smaller desmoid tumor, however, was identified only at tomo...

متن کامل

Digital Breast Tomosynthesis - 06/13

Digital breast tomosynthesis (DBT) is being developed as an approach to generate images that may improve the sensitivity and specificity of mammography. Current radiographic approaches to mammography produce two-dimensional (2D) images. These 2D systems can have limitations due to overlapping tissue in the breast that may hide lesions (cancers) or cause benign masses to appear suspicious. DBT, ...

متن کامل

MM.05.012 Digital Breast Tomosynthesis - 8/14

Digital breast tomosynthesis (DBT) is being developed as an approach to generate images that may improve the sensitivity and specificity of mammography. Current radiographic approaches to mammography produce two-dimensional (2D) images. These 2D systems can have limitations due to overlapping tissue in the breast that may hide lesions (cancers) or cause benign masses to appear suspicious. DBT, ...

متن کامل

Optimization of Digital Breast Tomosynthesis (DBT) for Breast Cancer Diagnosis

Recent papers have reported the usefulness of DBT as the latest diagnostic modality for breast cancer [1]-[6]. In this chapter, the author describes clinical evaluation of the usefulness regarding DBT with reference to other diagnostic modalities such as Full Field Digital Mammography (FFDM), contrast-enhanced (CE) MRI, contrast-enhanced (CE) CT, and ultrasound (US) in accordance with prelimina...

متن کامل

Visualization of Breast Microcalcifications on Digital Breast Tomosynthesis and 2-Dimensional Digital Mammography Using Specimens

PURPOSE The purpose of this study is to compare the visibility of microcalcifications of digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) using breast specimens. MATERIALS AND METHODS Thirty-one specimens' DBT and FFDM were retrospectively reviewed by four readers. RESULTS The image quality of microcalcifications of DBT was rated as superior or equivalent in 71.0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiology management

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2005