Bioengineering reasons for the failure of metal-on-metal hip prostheses: an engineer's perspective.

نویسنده

  • J Fisher
چکیده

Bioengineering reasons for increased wear and failure of metal-on-metal (MoM) bearings in hip prostheses have been described. Low wear occurs in MoM hips when the centre of the femoral head is concentric with the centre of the acetabular component and the implants are correctly positioned. Translational or rotational malpositioning of the components can lead to the contact-patch of the femoral component being displaced to the rim of the acetabular component, resulting in a ten- to 100-fold increase in wear and metal ion levels. This may cause adverse tissue reactions, loosening of components and failure of the prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

(v) Simulation and measurement of wear in metal-on-metal bearings in vitro- understanding the reasons for increased wear

A new Stratified Approach For Enhanced Reliability (SAFER) pre-clinical simulation testing of joint prostheses has been described in a preceding paper in this volume. The application of SAFER in vitro simulation and testing to metal-on-metal bearings is described in this review paper. The review aims to provide further understanding of the reasons for, and causes of, increased wear in metal-on-...

متن کامل

Complications Related to Metal-on-Metal Articulation in Trapeziometacarpal Joint Total Joint Arthroplasty

Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation, and we present two cases of failure of MoM prostheses due to elevated metal-serum levels in one ...

متن کامل

Taper junction failure in large-diameter metal-on-metal bearings

OBJECTIVES An ongoing prospective study to investigate failing metal-on-metal hip prostheses was commenced at our centre in 2008. We report on the results of the analysis of the first consecutive 126 failed mated total hip prostheses from a single manufacturer. METHODS Analysis was carried out using highly accurate coordinate measuring to calculate volumetric and linear rates of the articular...

متن کامل

Influence of Bearing Couple, Lubricant and Swing Phase Load Conditions on the Friction of 28mm Hip Replacements

INTRODUCTION The majority of current artificial hip implants use a material combination of ultra-high molecular-weight polyethylene against metal or ceramic. However, it is well documented that the wear debris from these prostheses contributes to osteolysis and ultimate failure of the prosthesis, hence alternative materials have been sought, such as metalon-metal and ceramic-on-ceramic [1]. Mor...

متن کامل

Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints

BACKGROUND AND PURPOSE Particles originating from the articulating surfaces of hip endoprostheses often induce an inflammatory response, which can be related to implant failure. We therefore analyzed the metal content in capsular tissue from 44 McKee-Farrar metal-on-metal hip prostheses (with 3 different head sizes) and we also analyzed the morphological structure of layers located on articulat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 8  شماره 

صفحات  -

تاریخ انتشار 2011