Effects of Geometrical Uncertainties on Whole Breast Radiotherapy: A Comparison of Four Different Techniques

نویسندگان

  • Naoki Nakamura
  • Osamu Takahashi
  • Minobu Kamo
  • Shogo Hatanaka
  • Haruna Endo
  • Norifumi Mizuno
  • Naoto Shikama
  • Mami Ogita
  • Kenji Sekiguchi
چکیده

PURPOSE The purpose of this study was to quantify the target coverage, homogeneity, and robustness of the dose distributions against geometrical uncertainties associated with four whole breast radiotherapy techniques. METHODS The study was based on the planning-computed tomography-datasets of 20 patients who underwent whole breast radiotherapy. A total of four treatment plans (wedge, field-in-field [FIF], hybrid intensity-modulated radiotherapy [IMRT], and full IMRT) were created for each patient. The hybrid IMRT plans comprised two opposed tangential open beams plus two IMRT beams. Setup errors were simulated by moving the beam isocenters by 5 mm in the anterior or posterior direction. RESULTS With the original plan, the wedge technique yielded a high volume receiving ≥107% of the prescription dose (V107; 7.5%±4.2%), whereas the other three techniques yielded excellent target coverage and homogeneity. A 5 mm anterior displacement caused a large and significant increase in the V107 (+5.2%±4.1%, p<0.01) with the FIF plan, but not with the hybrid IMRT (+0.4%±1.2%, p=0.11) or full IMRT (+0.7%±1.8%, p=0.10) plan. A 5-mm posterior displacement caused a large decrease in the V95 with the hybrid IMRT (-2.5%±3.7%, p<0.01) and full IMRT (-4.3%±5.1%, p<0.01) plans, but not with the FIF plan (+0.1%±0.7%, p=0.74). The decrease in V95 was significantly smaller with the hybrid IMRT plan than with the full IMRT plan (p<0.01). CONCLUSION The FIF, hybrid IMRT, and full IMRT plans offered excellent target coverage and homogeneity. Hybrid IMRT provided better robustness against geometrical uncertainties than full IMRT, whereas FIF provided comparable robustness to that of hybrid IMRT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

A comparison of contralateral breast dose due to breast cancer radiotherapy using two different treatment machines in a radiotherapy center

Background: The radiation dose received by contralateral breast (CLB) is one of the concerns of breast radiotherapy, because it may lead to the induction of secondary breast cancer. The aim of this study was to evaluate the CLB surface dose in the breast treatment in Yazd radiotherapy center. Materials and Methods: The surface dose of CLB was measured using TLD dosimetry in 50 cancer breast pat...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.

Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiven...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2014