Tuning of AcurosXB source size setting for small intracranial targets

نویسندگان

  • Stephen J. Gardner
  • Siming Lu
  • Chang Liu
  • Ning Wen
  • Indrin J. Chetty
چکیده

This study details a method to evaluate the source size selection for small field intracranial stereotactic radiosurgery (SRS) deliveries in Eclipse treatment planning system (TPS) for AcurosXB dose calculation algorithm. Our method uses end-to-end dosimetric data to evaluate a total of five source size selections (0.50 mm, 0.75 mm, 1.00 mm, 1.25 mm, and 1.50 mm). The dosimetric leaf gap (DLG) was varied in this analysis (three DLG values were tested for each scenario). We also tested two MLC leaf designs (standard and high-definition MLC) and two delivery types for intracranial SRS (volumetric modulated arc therapy [VMAT] and dynamic conformal arc [DCA]). Thus, a total of 10 VMAT plans and 10 DCA plans were tested for each machine type (TrueBeam [standard MLC] and Edge [high-definition MLC]). Each plan was mapped to a solid water phantom and dose was calculated with each iteration of source size and DLG value (15 total dose calculations for each plan). To measure the dose, Gafchromic film was placed in the coronal plane of the solid water phantom at isocenter. The phantom was localized via on-board CBCT and the plans were delivered at planned gantry, collimator, and couch angles. The planned and measured film dose was compared using Gamma (3.0%, 0.3 mm) criteria. The vendor-recommended 1.00 mm source size was suitable for TrueBeam planning (both VMAT and DCA planning) and Edge DCA planning. However, for Edge VMAT planning, the 0.50 mm source size yielded the highest passing rates. The difference in dose calculation among the source size variations manifested primarily in two regions of the dose calculation: (1) the shoulder of the high-dose region, and (2) for small targets (volume ≤ 0.30 cc), in the central portion of the high-dose region. Selection of a larger than optimal source size can result in increased blurring of the shoulder for all target volume sizes tested, and can result in central axis dose discrepancies in excess of 10% for target volumes sizes ≤ 0.30 cc. Our results indicate a need for evaluation of the source size when AcurosXB is used to model intracranial SRS delivery, and our methods represent a feasible process for many clinics to perform tuning of the AcurosXB source size parameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Economics of Fertility Management of Small Holding Dairy Farms in Bangladesh

Considering different fertility traits 411 cows from 73 farms used for economic analyses. From these, 202 lactating cows were selected for evaluating the fertility status. Pre-tested data sheets were used to record the socioeconomic status of the farms including their assets, cost and return and productive and reproductive performance of the dairy cows. Targets were set considering the situatio...

متن کامل

A Non-radial Approach for Setting Integer-valued Targets in Data Envelopment Analysis

Data Envelopment Analysis (DEA) has been widely studied in the literature since its inception with Charnes, Cooper and Rhodes work in 1978. The methodology behind the classical DEA method is to determine how much improvements in the outputs (inputs) dimensions is necessary in order to render them efficient. One of the underlying assumptions of this methodology is that the units consume and prod...

متن کامل

An Improvement over Random Early Detection Algorithm: A Self-Tuning Approach

Random Early Detection (RED) is one of the most commonly used Active Queue Management (AQM) algorithms that is recommended by IETF for deployment in the network. Although RED provides low average queuing delay and high throughput at the same time, but effectiveness of RED is highly sensitive to the RED parameters setting. As network condition varies largely, setting RED's parameters with fixed ...

متن کامل

Size tuning in the absence of spatial frequency tuning in object recognition

How do we attend to objects at a variety of sizes as we view our visual world? Because of an advantage in identification of lowpass over highpass filtered patterns, as well as large over small images, a number of theorists have assumed that size-independent recognition is achieved by spatial frequency (SF) based coarse-to-fine tuning. We found that the advantage of large sizes or low SFs was lo...

متن کامل

A sequence of targets toward a common best practice frontier in DEA

Original data envelopment analysis models treat decision-making units as independent entities. This feature of data envelopment analysis results in significant diversity in input and output weights, which is irrelevant and problematic from the managerial point of view. In this regard, several methodologies have been developed to measure the efficiency scores based on common weights. Specificall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017