Scanning laser Doppler is a useful technique to assess foot cutaneous perfusion during femoral artery cannulation
نویسندگان
چکیده
BACKGROUND: Measurement of cardiac output and extravascular lung water in critically ill patients using femoral artery double-indicator dilution involves femoral artery catheterization. The potential risk of vascular compromise to the limb may be exacerbated in patients receiving vasopressors. The utility of scanning laser Doppler flowmetry to measure changes in pedal perfusion following catheterization was assessed. RESULTS: There were no significant changes in mean occlusion pressures or in cutaneous perfusion between either leg or between measurement time points, immediately after or 24 h following insertion of the catheters. CONCLUSIONS: Scanning laser Doppler flowmetry is easily used to assess changes in foot perfusion and the effect of interventions that may reduce blood flow to the skin of the foot. Femoral artery catheterization for double-indicator dilution measurements does not reduce calf occlusion pressures or foot skin perfusion in patients receiving vasopressor drugs.
منابع مشابه
Femoral or axillary artery as a cannulation site in the acute aortic dissection type A surgery: is there still a doubt?
Background Anterograde perfusion is widely addopted strategy in aortic dissection type A treatement. Physiological blood flow direction reduces malperfusion complications during CPB and allows anterograde cerebral perfusion during circulatory arrest. In spite of these facts, femoral artery is still used as a cannulation site by surgeons worldwide. Primary end point was to analize the mortality ...
متن کاملMid-term results of peripheric cannulation after port-access surgery.
Several minimally invasive approaches, avoiding median sternotomy, have been described within the last few years for cardiac surgery. Femoral arterial and venous cannulation for extracorporeal perfusion are required for many of these operations. The aim of this report is to assess the long-term outcomes of femoral cannulations in patients who underwent minimally invasive procedures. One hundred...
متن کاملThe cannulation strategy in surgery for acute type A dissection
The rates of mortality and morbidity remain high in surgery for acute type A dissection. There is controversy regarding the best cannulation strategy for achieving good clinical results. Each cannulation technique has different anatomical characteristics and a different flow pattern inside the aorta during cardiopulmonary bypass. Some adverse, clinically important outcomes may be related to eve...
متن کاملAnalysis of collateral blood flow to the lower body during selective cerebral perfusion: is three-vessel perfusion better than two-vessel perfusion?
OBJECTIVE During selective cerebral perfusion (SCP), only the upper body is perfused. However, blood actually returns into the descending aorta through collaterals during SCP. This collateral blood flow (CBF) is thought to be important to protect the visceral organs and spinal cord from ischemia. The left subclavian artery is postulated to be important as a collateral source to the lower body. ...
متن کاملPerfusion of the femoral head during surgical dislocation of the hip. Monitoring by laser Doppler flowmetry.
We used laser Doppler flowmetry (LDF) with a high energy (20 mW) laser to measure perfusion of the femoral head intraoperatively in 32 hips. The surgical procedure was joint debridement requiring dislocation or subluxation of the hip. The laser probe was placed within the anterosuperior quadrant of the femoral head. Blood flow was monitored in specific positions of the hip before and after disl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Critical Care
دوره 3 شماره
صفحات -
تاریخ انتشار 1999